Verification of the indoor GPS system, by comparison with calibrated coordinates and by angular reference

Jody E Muelaner, Zheng Wang, Oliver Martin, Jafar Jamshidi, Paul G Maropoulos

Research output: Contribution to journalArticlepeer-review

34 Citations (SciVal)
197 Downloads (Pure)

Abstract

This paper details work carried out to verify the dimensional measurement performance of the Indoor GPS (iGPS) system; a network of Rotary-Laser Automatic Theodolites (R-LATs). Initially tests were carried out to determine the angular uncertainties on an individual R-LAT transmitter-receiver pair. A method is presented of determining the uncertainty of dimensional measurement for a three dimensional coordinate measurement machine. An experimental procedure was developed to compare three dimensional coordinate measurements with calibrated reference points. The reference standard used to calibrate these reference points was a fringe counting interferometer with the multilateration technique employed to establish three dimensional coordinates. This is an extension of the established technique of comparing measured lengths with calibrated lengths. The method was found to be practical and able to establish that the expanded uncertainty of the basic iGPS system was approximately 1 mm at a 95% confidence level. Further tests carried out on a highly optimized version of the iGPS system have shown that the coordinate uncertainty can be reduced to 0.25 mm at a 95% confidence level.
Original languageEnglish
Pages (from-to)2323-2331
Number of pages10
JournalJournal of Intelligent Manufacturing
Volume23
Issue number6
DOIs
Publication statusPublished - Dec 2012

Fingerprint

Dive into the research topics of 'Verification of the indoor GPS system, by comparison with calibrated coordinates and by angular reference'. Together they form a unique fingerprint.

Cite this