Projects per year
Abstract
Background: Stud design is critical in modulating impact forces between the football boot and the turf, yet most systems prioritize traction using rigid materials, largely neglecting the role of material flexibility in load attenuation. This approach contrasts with the need to mitigate highly impulsive forces that occur during early stance in injury-prone maneuvers.
Hypothesis/Purpose: Replacing traditional rigid studs with more flexible alternatives would reduce the magnitude and increase the time-to-peak of key lower limb loading variables. The purpose was to assess the biomechanical effects of two novel flexible stud designs compared to a traditional rigid one during football-specific cutting and landing tasks.
Study Design: Crossover Study Design.
Methods: Fourteen male recreational players performed a planned 90° cut, a 180° cut, and a single-leg drop-land-and-cut on dry 3G turf wearing the same boot with three different stud sets: rigid (STD), flexible (OPT), more flexible (FLX). Data analysis included scalar comparisons (approach speed, stance time, loading rates) and full-waveform analysis: amplitude-phase registration on GRF only, along with Statistical Parametric Mapping of GRF, knee kinematics, and moments. Subjective perception was assessed via Visual Analog Scale.
Results: Participants rated flexible studs higher for stability, comfort and overall appreciation. Approach speed and stance time were invariant across conditions. In 180° cuts, loading rates were higher with STD than FLX in both vertical (+33.42%) and medio-lateral directions (+36.91%). Amplitude-phase analysis showed significant GRF anticipations in some early phases of stance with STD compared to FLX. In 90° cuts, the pattern was similar: higher medio-lateral loading rate with STD vs FLX (+25.06%) and STD inducing earlier GRF onsets. Knee dynamics were did not show evidence of change.
Conclusion:
Increasing stud flexibility affected the timing of early load uptake - delaying and flattening the initial GRF rise - while improving perceived stability/comfort and preserving perceived grip.
Clinical Relevance: This exploratory study identifies stud flexibility as an actionable design lever to mitigate highly impulsive loading, providing a mechanism for attenuating lower-limb load exposures in early stance—a period highly relevant to non-contact ACL injury risk— showing better subjective perception of comfort and stability and without degrading overall player performance.
Hypothesis/Purpose: Replacing traditional rigid studs with more flexible alternatives would reduce the magnitude and increase the time-to-peak of key lower limb loading variables. The purpose was to assess the biomechanical effects of two novel flexible stud designs compared to a traditional rigid one during football-specific cutting and landing tasks.
Study Design: Crossover Study Design.
Methods: Fourteen male recreational players performed a planned 90° cut, a 180° cut, and a single-leg drop-land-and-cut on dry 3G turf wearing the same boot with three different stud sets: rigid (STD), flexible (OPT), more flexible (FLX). Data analysis included scalar comparisons (approach speed, stance time, loading rates) and full-waveform analysis: amplitude-phase registration on GRF only, along with Statistical Parametric Mapping of GRF, knee kinematics, and moments. Subjective perception was assessed via Visual Analog Scale.
Results: Participants rated flexible studs higher for stability, comfort and overall appreciation. Approach speed and stance time were invariant across conditions. In 180° cuts, loading rates were higher with STD than FLX in both vertical (+33.42%) and medio-lateral directions (+36.91%). Amplitude-phase analysis showed significant GRF anticipations in some early phases of stance with STD compared to FLX. In 90° cuts, the pattern was similar: higher medio-lateral loading rate with STD vs FLX (+25.06%) and STD inducing earlier GRF onsets. Knee dynamics were did not show evidence of change.
Conclusion:
Increasing stud flexibility affected the timing of early load uptake - delaying and flattening the initial GRF rise - while improving perceived stability/comfort and preserving perceived grip.
Clinical Relevance: This exploratory study identifies stud flexibility as an actionable design lever to mitigate highly impulsive loading, providing a mechanism for attenuating lower-limb load exposures in early stance—a period highly relevant to non-contact ACL injury risk— showing better subjective perception of comfort and stability and without degrading overall player performance.
| Original language | English |
|---|---|
| Article number | SPH-26-0096 |
| Journal | Sports Health |
| Publication status | Acceptance date - 18 Jun 2026 |
Funding
S. Fantozzi received funding Saspick to cover consumable costs and travel expenses related to the execution of this study
Fingerprint
Dive into the research topics of 'The effect of stud flexibility on lower limb biomechanical demands in football-specific movements'. Together they form a unique fingerprint.Projects
- 1 Finished
-
The effect of different stud designs on lower limb biomechanical demands in football-specific movements
Preatoni, E. (CoPI) & Fantozzi, S. (CoPI)
24/10/24 → 30/04/25
Project: Other
Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS