Testing, numerical simulation and design of prestressed high strength steel arched trusses

Sheida Afshan, Marios Theofanous, Jie Wang, M. Gkantou, Leroy Gardner

Research output: Contribution to journalArticle

Abstract

The structural behaviour of prestressed high strength steel arched trusses is studied in this paper through experimentation and numerical modelling. Four 11 m span prestressed arched trusses fabricated from S460 hot finished square hollow section members were loaded vertically to failure. Three of the tested trusses were prestressed to different levels by means of a 7-wire strand cable housed within the bottom chord, while the fourth truss contained no cable and served as a control specimen. Each truss was loaded at five points coinciding with joint locations along its span, and the recorded load-deformation responses at each loading point are presented. Inclusion and prestressing of the cable was shown to delay yielding of the bottom chord and enhance the load carrying capacity of the trusses, which ultimately failed by either in-plane or out-of-plane buckling of the top chord. For the tested trusses, around 40% increases in structural resistance were achieved through the addition of the cable, though the self-weight was increased by only approximately 3%. In parallel with the experimental programme, a finite element model was developed and validated against the test results. Upon successful replication of the experimentally observed structural response of the trusses, parametric studies were conducted to investigate the effect of key parameters such as prestress level, material grade and the top chord cross-section on the overall structural response. Based on both the experimental and numerical results, design recommendations in the form of simple design checks to be performed for such systems are provided.
Original languageEnglish
Pages (from-to)510-522
Number of pages13
JournalEngineering Structures
Volume183
Early online date15 Jan 2019
DOIs
Publication statusPublished - 15 Mar 2019

Keywords

  • Cable-in-tube system
  • Experimentation
  • Finite element modelling
  • High strength steel
  • Prestressing
  • Testing
  • Trusses

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Building and Construction

Cite this

Testing, numerical simulation and design of prestressed high strength steel arched trusses. / Afshan, Sheida; Theofanous, Marios ; Wang, Jie; Gkantou, M.; Gardner, Leroy.

In: Engineering Structures, Vol. 183, 15.03.2019, p. 510-522.

Research output: Contribution to journalArticle

Afshan, Sheida ; Theofanous, Marios ; Wang, Jie ; Gkantou, M. ; Gardner, Leroy. / Testing, numerical simulation and design of prestressed high strength steel arched trusses. In: Engineering Structures. 2019 ; Vol. 183. pp. 510-522.
@article{5438d42e52e84a7b9f397a16bd03fc43,
title = "Testing, numerical simulation and design of prestressed high strength steel arched trusses",
abstract = "The structural behaviour of prestressed high strength steel arched trusses is studied in this paper through experimentation and numerical modelling. Four 11 m span prestressed arched trusses fabricated from S460 hot finished square hollow section members were loaded vertically to failure. Three of the tested trusses were prestressed to different levels by means of a 7-wire strand cable housed within the bottom chord, while the fourth truss contained no cable and served as a control specimen. Each truss was loaded at five points coinciding with joint locations along its span, and the recorded load-deformation responses at each loading point are presented. Inclusion and prestressing of the cable was shown to delay yielding of the bottom chord and enhance the load carrying capacity of the trusses, which ultimately failed by either in-plane or out-of-plane buckling of the top chord. For the tested trusses, around 40{\%} increases in structural resistance were achieved through the addition of the cable, though the self-weight was increased by only approximately 3{\%}. In parallel with the experimental programme, a finite element model was developed and validated against the test results. Upon successful replication of the experimentally observed structural response of the trusses, parametric studies were conducted to investigate the effect of key parameters such as prestress level, material grade and the top chord cross-section on the overall structural response. Based on both the experimental and numerical results, design recommendations in the form of simple design checks to be performed for such systems are provided.",
keywords = "Cable-in-tube system, Experimentation, Finite element modelling, High strength steel, Prestressing, Testing, Trusses",
author = "Sheida Afshan and Marios Theofanous and Jie Wang and M. Gkantou and Leroy Gardner",
year = "2019",
month = "3",
day = "15",
doi = "10.1016/j.engstruct.2019.01.007",
language = "English",
volume = "183",
pages = "510--522",
journal = "Engineering Structures",
issn = "0141-0296",
publisher = "Elsevier",

}

TY - JOUR

T1 - Testing, numerical simulation and design of prestressed high strength steel arched trusses

AU - Afshan, Sheida

AU - Theofanous, Marios

AU - Wang, Jie

AU - Gkantou, M.

AU - Gardner, Leroy

PY - 2019/3/15

Y1 - 2019/3/15

N2 - The structural behaviour of prestressed high strength steel arched trusses is studied in this paper through experimentation and numerical modelling. Four 11 m span prestressed arched trusses fabricated from S460 hot finished square hollow section members were loaded vertically to failure. Three of the tested trusses were prestressed to different levels by means of a 7-wire strand cable housed within the bottom chord, while the fourth truss contained no cable and served as a control specimen. Each truss was loaded at five points coinciding with joint locations along its span, and the recorded load-deformation responses at each loading point are presented. Inclusion and prestressing of the cable was shown to delay yielding of the bottom chord and enhance the load carrying capacity of the trusses, which ultimately failed by either in-plane or out-of-plane buckling of the top chord. For the tested trusses, around 40% increases in structural resistance were achieved through the addition of the cable, though the self-weight was increased by only approximately 3%. In parallel with the experimental programme, a finite element model was developed and validated against the test results. Upon successful replication of the experimentally observed structural response of the trusses, parametric studies were conducted to investigate the effect of key parameters such as prestress level, material grade and the top chord cross-section on the overall structural response. Based on both the experimental and numerical results, design recommendations in the form of simple design checks to be performed for such systems are provided.

AB - The structural behaviour of prestressed high strength steel arched trusses is studied in this paper through experimentation and numerical modelling. Four 11 m span prestressed arched trusses fabricated from S460 hot finished square hollow section members were loaded vertically to failure. Three of the tested trusses were prestressed to different levels by means of a 7-wire strand cable housed within the bottom chord, while the fourth truss contained no cable and served as a control specimen. Each truss was loaded at five points coinciding with joint locations along its span, and the recorded load-deformation responses at each loading point are presented. Inclusion and prestressing of the cable was shown to delay yielding of the bottom chord and enhance the load carrying capacity of the trusses, which ultimately failed by either in-plane or out-of-plane buckling of the top chord. For the tested trusses, around 40% increases in structural resistance were achieved through the addition of the cable, though the self-weight was increased by only approximately 3%. In parallel with the experimental programme, a finite element model was developed and validated against the test results. Upon successful replication of the experimentally observed structural response of the trusses, parametric studies were conducted to investigate the effect of key parameters such as prestress level, material grade and the top chord cross-section on the overall structural response. Based on both the experimental and numerical results, design recommendations in the form of simple design checks to be performed for such systems are provided.

KW - Cable-in-tube system

KW - Experimentation

KW - Finite element modelling

KW - High strength steel

KW - Prestressing

KW - Testing

KW - Trusses

UR - http://www.scopus.com/inward/record.url?scp=85059854043&partnerID=8YFLogxK

U2 - 10.1016/j.engstruct.2019.01.007

DO - 10.1016/j.engstruct.2019.01.007

M3 - Article

VL - 183

SP - 510

EP - 522

JO - Engineering Structures

JF - Engineering Structures

SN - 0141-0296

ER -