Abstract

The dynamic behaviour of timber structures in service is becoming a more important consideration in design as modern engineered wood products allow longer spans and taller timber buildings, which can be sensitive to dynamic loading such as that from wind or footfall. Connections in timber structures have a pronounced effect on their structural behaviour. In dowel-type connections, the fasteners bend under load and embed into the surrounding timber and, since embedment is a nonlinear process, the stiffness of those connections varies depending on the nature of the applied load. Here, single-dowel connections are tested under cyclic loads representative of in-service vibration. One-sided and reversed cyclic loads are applied. The specimen stiffness is observed to reduce with the amplitude of one-sided cyclic load. For small-amplitude one-sided load, the specimen stiffness is seen to tend towards that predicted
Original languageEnglish
Pages (from-to)21-29
Number of pages9
JournalEngineering Structures
Volume65
DOIs
Publication statusPublished - 15 Apr 2014

Fingerprint

Timber
Cyclic loads
Stiffness
Wood products
Fasteners
Loads (forces)

Cite this

Stiffness of dowel-type timber connections under pre-yield oscillating loads. / Reynolds, Thomas; Harris, Richard; Chang, Wen-Shao.

In: Engineering Structures, Vol. 65, 15.04.2014, p. 21-29.

Research output: Contribution to journalArticle

Reynolds, Thomas ; Harris, Richard ; Chang, Wen-Shao. / Stiffness of dowel-type timber connections under pre-yield oscillating loads. In: Engineering Structures. 2014 ; Vol. 65. pp. 21-29.
@article{87f23b061c2c451593a9ba3ea5716724,
title = "Stiffness of dowel-type timber connections under pre-yield oscillating loads",
abstract = "The dynamic behaviour of timber structures in service is becoming a more important consideration in design as modern engineered wood products allow longer spans and taller timber buildings, which can be sensitive to dynamic loading such as that from wind or footfall. Connections in timber structures have a pronounced effect on their structural behaviour. In dowel-type connections, the fasteners bend under load and embed into the surrounding timber and, since embedment is a nonlinear process, the stiffness of those connections varies depending on the nature of the applied load. Here, single-dowel connections are tested under cyclic loads representative of in-service vibration. One-sided and reversed cyclic loads are applied. The specimen stiffness is observed to reduce with the amplitude of one-sided cyclic load. For small-amplitude one-sided load, the specimen stiffness is seen to tend towards that predicted",
author = "Thomas Reynolds and Richard Harris and Wen-Shao Chang",
year = "2014",
month = "4",
day = "15",
doi = "10.1016/j.engstruct.2014.01.024",
language = "English",
volume = "65",
pages = "21--29",
journal = "Engineering Structures",
issn = "0141-0296",
publisher = "Elsevier",

}

TY - JOUR

T1 - Stiffness of dowel-type timber connections under pre-yield oscillating loads

AU - Reynolds, Thomas

AU - Harris, Richard

AU - Chang, Wen-Shao

PY - 2014/4/15

Y1 - 2014/4/15

N2 - The dynamic behaviour of timber structures in service is becoming a more important consideration in design as modern engineered wood products allow longer spans and taller timber buildings, which can be sensitive to dynamic loading such as that from wind or footfall. Connections in timber structures have a pronounced effect on their structural behaviour. In dowel-type connections, the fasteners bend under load and embed into the surrounding timber and, since embedment is a nonlinear process, the stiffness of those connections varies depending on the nature of the applied load. Here, single-dowel connections are tested under cyclic loads representative of in-service vibration. One-sided and reversed cyclic loads are applied. The specimen stiffness is observed to reduce with the amplitude of one-sided cyclic load. For small-amplitude one-sided load, the specimen stiffness is seen to tend towards that predicted

AB - The dynamic behaviour of timber structures in service is becoming a more important consideration in design as modern engineered wood products allow longer spans and taller timber buildings, which can be sensitive to dynamic loading such as that from wind or footfall. Connections in timber structures have a pronounced effect on their structural behaviour. In dowel-type connections, the fasteners bend under load and embed into the surrounding timber and, since embedment is a nonlinear process, the stiffness of those connections varies depending on the nature of the applied load. Here, single-dowel connections are tested under cyclic loads representative of in-service vibration. One-sided and reversed cyclic loads are applied. The specimen stiffness is observed to reduce with the amplitude of one-sided cyclic load. For small-amplitude one-sided load, the specimen stiffness is seen to tend towards that predicted

UR - http://www.scopus.com/inward/record.url?scp=84894679634&partnerID=8YFLogxK