Measurement of positive displacement pump and motor noise using sound intensity techniques

Z Ngah, K A Edge

Research output: Contribution to conferencePaper

Abstract

The noise levels generated by a variable capacity axial piston pump and a fixed capacity axial piston motor have been measured using Sound Intensity techniques; no special acoustic test environment was employed. The experimental procedures followed, as closely as possible, draft International Standard ISO/DIS 9614-4. Because the machines were mounted on existing test stands it was found difficult to comply completely with the requirements laid down in the draft Standard. Typical test results are presented showing that pump overall Sound Pressure levels increase significantly with increasing delivery pressure. The effect of discharge pipe length on pump noise levels is relatively small. From the motor noise tests, it was found that variations in speed were much more important than load. The work has highlighted the need for the development of Sound Intensity procedures specifically concerned with fluid power pumps and motors
Original languageEnglish
Pages1-6
Number of pages6
Publication statusPublished - 1991
EventOff-highway Powerplant Congress and Exposition - Milwaukee, WI, USA United States
Duration: 1 Sep 2001 → …

Conference

ConferenceOff-highway Powerplant Congress and Exposition
CountryUSA United States
CityMilwaukee, WI
Period1/09/01 → …

Fingerprint

Acoustic intensity
Acoustic noise
Pumps
Reciprocating pumps
Pistons
Acoustics
Pipe
Acoustic waves
Fluids

Cite this

Ngah, Z., & Edge, K. A. (1991). Measurement of positive displacement pump and motor noise using sound intensity techniques. 1-6. Paper presented at Off-highway Powerplant Congress and Exposition, Milwaukee, WI, USA United States.

Measurement of positive displacement pump and motor noise using sound intensity techniques. / Ngah, Z; Edge, K A.

1991. 1-6 Paper presented at Off-highway Powerplant Congress and Exposition, Milwaukee, WI, USA United States.

Research output: Contribution to conferencePaper

Ngah, Z & Edge, KA 1991, 'Measurement of positive displacement pump and motor noise using sound intensity techniques' Paper presented at Off-highway Powerplant Congress and Exposition, Milwaukee, WI, USA United States, 1/09/01, pp. 1-6.
Ngah Z, Edge KA. Measurement of positive displacement pump and motor noise using sound intensity techniques. 1991. Paper presented at Off-highway Powerplant Congress and Exposition, Milwaukee, WI, USA United States.
Ngah, Z ; Edge, K A. / Measurement of positive displacement pump and motor noise using sound intensity techniques. Paper presented at Off-highway Powerplant Congress and Exposition, Milwaukee, WI, USA United States.6 p.
@conference{66dd3fa8ca744f69936485dbc9135b01,
title = "Measurement of positive displacement pump and motor noise using sound intensity techniques",
abstract = "The noise levels generated by a variable capacity axial piston pump and a fixed capacity axial piston motor have been measured using Sound Intensity techniques; no special acoustic test environment was employed. The experimental procedures followed, as closely as possible, draft International Standard ISO/DIS 9614-4. Because the machines were mounted on existing test stands it was found difficult to comply completely with the requirements laid down in the draft Standard. Typical test results are presented showing that pump overall Sound Pressure levels increase significantly with increasing delivery pressure. The effect of discharge pipe length on pump noise levels is relatively small. From the motor noise tests, it was found that variations in speed were much more important than load. The work has highlighted the need for the development of Sound Intensity procedures specifically concerned with fluid power pumps and motors",
author = "Z Ngah and Edge, {K A}",
year = "1991",
language = "English",
pages = "1--6",
note = "Off-highway Powerplant Congress and Exposition ; Conference date: 01-09-2001",

}

TY - CONF

T1 - Measurement of positive displacement pump and motor noise using sound intensity techniques

AU - Ngah, Z

AU - Edge, K A

PY - 1991

Y1 - 1991

N2 - The noise levels generated by a variable capacity axial piston pump and a fixed capacity axial piston motor have been measured using Sound Intensity techniques; no special acoustic test environment was employed. The experimental procedures followed, as closely as possible, draft International Standard ISO/DIS 9614-4. Because the machines were mounted on existing test stands it was found difficult to comply completely with the requirements laid down in the draft Standard. Typical test results are presented showing that pump overall Sound Pressure levels increase significantly with increasing delivery pressure. The effect of discharge pipe length on pump noise levels is relatively small. From the motor noise tests, it was found that variations in speed were much more important than load. The work has highlighted the need for the development of Sound Intensity procedures specifically concerned with fluid power pumps and motors

AB - The noise levels generated by a variable capacity axial piston pump and a fixed capacity axial piston motor have been measured using Sound Intensity techniques; no special acoustic test environment was employed. The experimental procedures followed, as closely as possible, draft International Standard ISO/DIS 9614-4. Because the machines were mounted on existing test stands it was found difficult to comply completely with the requirements laid down in the draft Standard. Typical test results are presented showing that pump overall Sound Pressure levels increase significantly with increasing delivery pressure. The effect of discharge pipe length on pump noise levels is relatively small. From the motor noise tests, it was found that variations in speed were much more important than load. The work has highlighted the need for the development of Sound Intensity procedures specifically concerned with fluid power pumps and motors

M3 - Paper

SP - 1

EP - 6