Load transfer in the proximal tibia following implantation with a unicompartmental knee replacement: a static snapshot

D. J. Simpson, B. J. L. Kendrick, C. A. F. Dodd, A. J. Price, H. S. Gill, D. W. Murray

Research output: Contribution to journalArticle

11 Citations (Scopus)

Abstract

Unicompartmental knee replacement (UKR) is an appealing alternative to total knee replacement when the patient has isolated medial compartment osteoarthritis. A common observation post-operatively is radiolucency between the tibial tray wall and the bone. In addition, some patients complain of persistent pain over the proximal tibia antero-medially; this may be related to elevated bone strains in the tibia. Currently, there is no intentionally made mechanical bond between the vertical wall of an Oxford UKR and the adjacent bone; whether one exists or not will influence the load transmission in the proximal tibia and may affect the elevated tibia strain. The aim of this study was to investigate how introducing a mechanical tie between the tibial tray wall and the adjacent bone might alter the load carried into the tibia for both cemented and cementless UKRs. Strain energy density in the region of bone adjacent to the tray wall was considerably increased when a mechanical tie was introduced; this has the potential of reducing the likelihood of a radiolucency occurring in that region. Moreover, a mechanical tie had the effect of reducing proximal tibia strain, which may decrease the incidence of pain following implantation with a UKR.
Original languageEnglish
Pages (from-to)521-529
Number of pages9
JournalProceedings of the Institution of Mechanical Engineers, Part H - Journal of Engineering in Medicine
Volume225
Issue numberH5
DOIs
Publication statusPublished - 2011

Fingerprint

Knee prostheses
Bone
Strain energy

Cite this

Load transfer in the proximal tibia following implantation with a unicompartmental knee replacement: a static snapshot. / Simpson, D. J.; Kendrick, B. J. L.; Dodd, C. A. F.; Price, A. J.; Gill, H. S.; Murray, D. W.

In: Proceedings of the Institution of Mechanical Engineers, Part H - Journal of Engineering in Medicine, Vol. 225, No. H5, 2011, p. 521-529.

Research output: Contribution to journalArticle

@article{97bc91374ae941b69778ff2633d77b41,
title = "Load transfer in the proximal tibia following implantation with a unicompartmental knee replacement: a static snapshot",
abstract = "Unicompartmental knee replacement (UKR) is an appealing alternative to total knee replacement when the patient has isolated medial compartment osteoarthritis. A common observation post-operatively is radiolucency between the tibial tray wall and the bone. In addition, some patients complain of persistent pain over the proximal tibia antero-medially; this may be related to elevated bone strains in the tibia. Currently, there is no intentionally made mechanical bond between the vertical wall of an Oxford UKR and the adjacent bone; whether one exists or not will influence the load transmission in the proximal tibia and may affect the elevated tibia strain. The aim of this study was to investigate how introducing a mechanical tie between the tibial tray wall and the adjacent bone might alter the load carried into the tibia for both cemented and cementless UKRs. Strain energy density in the region of bone adjacent to the tray wall was considerably increased when a mechanical tie was introduced; this has the potential of reducing the likelihood of a radiolucency occurring in that region. Moreover, a mechanical tie had the effect of reducing proximal tibia strain, which may decrease the incidence of pain following implantation with a UKR.",
author = "Simpson, {D. J.} and Kendrick, {B. J. L.} and Dodd, {C. A. F.} and Price, {A. J.} and Gill, {H. S.} and Murray, {D. W.}",
year = "2011",
doi = "10.1177/2041303310395074",
language = "English",
volume = "225",
pages = "521--529",
journal = "Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine",
issn = "0954-4119",
publisher = "Sage Publications",
number = "H5",

}

TY - JOUR

T1 - Load transfer in the proximal tibia following implantation with a unicompartmental knee replacement: a static snapshot

AU - Simpson, D. J.

AU - Kendrick, B. J. L.

AU - Dodd, C. A. F.

AU - Price, A. J.

AU - Gill, H. S.

AU - Murray, D. W.

PY - 2011

Y1 - 2011

N2 - Unicompartmental knee replacement (UKR) is an appealing alternative to total knee replacement when the patient has isolated medial compartment osteoarthritis. A common observation post-operatively is radiolucency between the tibial tray wall and the bone. In addition, some patients complain of persistent pain over the proximal tibia antero-medially; this may be related to elevated bone strains in the tibia. Currently, there is no intentionally made mechanical bond between the vertical wall of an Oxford UKR and the adjacent bone; whether one exists or not will influence the load transmission in the proximal tibia and may affect the elevated tibia strain. The aim of this study was to investigate how introducing a mechanical tie between the tibial tray wall and the adjacent bone might alter the load carried into the tibia for both cemented and cementless UKRs. Strain energy density in the region of bone adjacent to the tray wall was considerably increased when a mechanical tie was introduced; this has the potential of reducing the likelihood of a radiolucency occurring in that region. Moreover, a mechanical tie had the effect of reducing proximal tibia strain, which may decrease the incidence of pain following implantation with a UKR.

AB - Unicompartmental knee replacement (UKR) is an appealing alternative to total knee replacement when the patient has isolated medial compartment osteoarthritis. A common observation post-operatively is radiolucency between the tibial tray wall and the bone. In addition, some patients complain of persistent pain over the proximal tibia antero-medially; this may be related to elevated bone strains in the tibia. Currently, there is no intentionally made mechanical bond between the vertical wall of an Oxford UKR and the adjacent bone; whether one exists or not will influence the load transmission in the proximal tibia and may affect the elevated tibia strain. The aim of this study was to investigate how introducing a mechanical tie between the tibial tray wall and the adjacent bone might alter the load carried into the tibia for both cemented and cementless UKRs. Strain energy density in the region of bone adjacent to the tray wall was considerably increased when a mechanical tie was introduced; this has the potential of reducing the likelihood of a radiolucency occurring in that region. Moreover, a mechanical tie had the effect of reducing proximal tibia strain, which may decrease the incidence of pain following implantation with a UKR.

UR - http://www.scopus.com/inward/record.url?scp=79961150491&partnerID=8YFLogxK

UR - http://dx.doi.org/10.1177/2041303310395074

U2 - 10.1177/2041303310395074

DO - 10.1177/2041303310395074

M3 - Article

VL - 225

SP - 521

EP - 529

JO - Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine

JF - Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine

SN - 0954-4119

IS - H5

ER -