Finite element modeling of resurfacing hip prosthesis: estimation of accuracy through experimental validation

F. Taddei, S. Martelli, H. S. Gill, L. Cristofolini, M. Viceconti

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

Metal-on-metal hip resurfacing is becoming increasingly popular, and a number of new devices have been recently introduced that, in the short term, appear to have satisfactory outcome but many questions are still open on the biomechanics of the resurfaced femur. This could be investigated by means of finite element analysis, but, in order to be effective in discerning potential critical conditions, the accuracy of the models' predictions should be assessed. The major goal of this study was to validate, through a combined experimental-numerical study, a finite element modeling procedure for the simulation of resurfaced femurs. In addition, a preliminary biomechanical analysis of the changes induced in the femoral neck biomechanics by the presence of the device was performed, under a physiologic range of hip joint reaction directions. For this purpose, in vitro tests and a finite element model based on the same specimen were developed using a cadaver femur. The study focused on the Conserve Plus, one of the most common contemporary resurfacing designs. Five loading configurations were identified to correspond to the extremes of physiological directions for the hip joint. The agreement between experimental measurements and numerical predictions was good both in the prediction of the femoral strains (R(2)>0.9), and in the prosthesis micromotions (error
Original languageEnglish
Article number021002
JournalJournal Of Biomechanical Engineering
Volume132
Issue number2
DOIs
Publication statusPublished - 2010

Fingerprint

Hip prostheses
Hip Prosthesis
Femur
Biomechanics
Hip Joint
Biomechanical Phenomena
Metals
Equipment and Supplies
Finite Element Analysis
Femur Neck
Thigh
Cadaver
Prostheses and Implants
Hip
Finite element method
Direction compound

Cite this

Finite element modeling of resurfacing hip prosthesis: estimation of accuracy through experimental validation. / Taddei, F.; Martelli, S.; Gill, H. S.; Cristofolini, L.; Viceconti, M.

In: Journal Of Biomechanical Engineering, Vol. 132, No. 2, 021002, 2010.

Research output: Contribution to journalArticle

@article{90d2a8eff2dd4152b0dbaa2f7cc8f706,
title = "Finite element modeling of resurfacing hip prosthesis: estimation of accuracy through experimental validation",
abstract = "Metal-on-metal hip resurfacing is becoming increasingly popular, and a number of new devices have been recently introduced that, in the short term, appear to have satisfactory outcome but many questions are still open on the biomechanics of the resurfaced femur. This could be investigated by means of finite element analysis, but, in order to be effective in discerning potential critical conditions, the accuracy of the models' predictions should be assessed. The major goal of this study was to validate, through a combined experimental-numerical study, a finite element modeling procedure for the simulation of resurfaced femurs. In addition, a preliminary biomechanical analysis of the changes induced in the femoral neck biomechanics by the presence of the device was performed, under a physiologic range of hip joint reaction directions. For this purpose, in vitro tests and a finite element model based on the same specimen were developed using a cadaver femur. The study focused on the Conserve Plus, one of the most common contemporary resurfacing designs. Five loading configurations were identified to correspond to the extremes of physiological directions for the hip joint. The agreement between experimental measurements and numerical predictions was good both in the prediction of the femoral strains (R(2)>0.9), and in the prosthesis micromotions (error",
author = "F. Taddei and S. Martelli and Gill, {H. S.} and L. Cristofolini and M. Viceconti",
year = "2010",
doi = "10.1115/1.4000065",
language = "English",
volume = "132",
journal = "Journal Of Biomechanical Engineering",
issn = "0148-0731",
publisher = "American Society of Mechanical Engineers (ASME)",
number = "2",

}

TY - JOUR

T1 - Finite element modeling of resurfacing hip prosthesis: estimation of accuracy through experimental validation

AU - Taddei, F.

AU - Martelli, S.

AU - Gill, H. S.

AU - Cristofolini, L.

AU - Viceconti, M.

PY - 2010

Y1 - 2010

N2 - Metal-on-metal hip resurfacing is becoming increasingly popular, and a number of new devices have been recently introduced that, in the short term, appear to have satisfactory outcome but many questions are still open on the biomechanics of the resurfaced femur. This could be investigated by means of finite element analysis, but, in order to be effective in discerning potential critical conditions, the accuracy of the models' predictions should be assessed. The major goal of this study was to validate, through a combined experimental-numerical study, a finite element modeling procedure for the simulation of resurfaced femurs. In addition, a preliminary biomechanical analysis of the changes induced in the femoral neck biomechanics by the presence of the device was performed, under a physiologic range of hip joint reaction directions. For this purpose, in vitro tests and a finite element model based on the same specimen were developed using a cadaver femur. The study focused on the Conserve Plus, one of the most common contemporary resurfacing designs. Five loading configurations were identified to correspond to the extremes of physiological directions for the hip joint. The agreement between experimental measurements and numerical predictions was good both in the prediction of the femoral strains (R(2)>0.9), and in the prosthesis micromotions (error

AB - Metal-on-metal hip resurfacing is becoming increasingly popular, and a number of new devices have been recently introduced that, in the short term, appear to have satisfactory outcome but many questions are still open on the biomechanics of the resurfaced femur. This could be investigated by means of finite element analysis, but, in order to be effective in discerning potential critical conditions, the accuracy of the models' predictions should be assessed. The major goal of this study was to validate, through a combined experimental-numerical study, a finite element modeling procedure for the simulation of resurfaced femurs. In addition, a preliminary biomechanical analysis of the changes induced in the femoral neck biomechanics by the presence of the device was performed, under a physiologic range of hip joint reaction directions. For this purpose, in vitro tests and a finite element model based on the same specimen were developed using a cadaver femur. The study focused on the Conserve Plus, one of the most common contemporary resurfacing designs. Five loading configurations were identified to correspond to the extremes of physiological directions for the hip joint. The agreement between experimental measurements and numerical predictions was good both in the prediction of the femoral strains (R(2)>0.9), and in the prosthesis micromotions (error

UR - http://www.scopus.com/inward/record.url?scp=77953522728&partnerID=8YFLogxK

UR - http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=20370239

UR - http://dx.doi.org/10.1115/1.4000065

U2 - 10.1115/1.4000065

DO - 10.1115/1.4000065

M3 - Article

VL - 132

JO - Journal Of Biomechanical Engineering

JF - Journal Of Biomechanical Engineering

SN - 0148-0731

IS - 2

M1 - 021002

ER -