Experimental validation of a finite element model of a composite tibia

H. A. Gray, A. B. Zavatsky, F. Taddei, L. Cristofolini, H. S. Gill

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

Composite bones are synthetic models made to simulate the mechanical behaviour of human bones. Finite element (FE) models of composite bone can be used to evaluate new and modified designs of joint prostheses and fixation devices. The aim of the current study was to create an FE model of a composite tibia and to validate it against results obtained from a comprehensive set of experiments. For this, 17 strain rosettes were attached to a composite tibia (model 3101, Pacific Research Laboratories, Vashon, Washington, USA). Surface strains and displacements were measured under 13 loading conditions. Two FE models were created on the basis of computed tomography scans. The models differed from each other in the mesh and material properties assigned. The experiments were simulated on them and the results compared with experimental results. The more accurate model was selected on the basis of regression analysis. In general, experimental strain measurements were highly repeatable and compared well with published results. The more accurate model, in which the inner elements representing the foam were assigned isotropic material properties and the elements representing the epoxy layer were assigned transversely isotropic material properties, was able to simulate the mechanical behaviour of the tibia with acceptable accuracy. The regression line for all axial loads combined had a slope of 0.999, an intercept of -6.24 microstrain, and an R2 value of 0.962. The root mean square error as a percentage was 5 per cent.
Original languageEnglish
Pages (from-to)315-324
Number of pages10
JournalProceedings of the Institution of Mechanical Engineers, Part H - Journal of Engineering in Medicine
Volume221
Issue number3
DOIs
Publication statusPublished - 2007

Fingerprint

Composite materials
Materials properties
Bone
Joint prostheses
Strain measurement
Axial loads
Research laboratories
Regression analysis
Mean square error
Tomography
Foams
Experiments

Cite this

Experimental validation of a finite element model of a composite tibia. / Gray, H. A.; Zavatsky, A. B.; Taddei, F.; Cristofolini, L.; Gill, H. S.

In: Proceedings of the Institution of Mechanical Engineers, Part H - Journal of Engineering in Medicine, Vol. 221, No. 3, 2007, p. 315-324.

Research output: Contribution to journalArticle

@article{65c7b93f6e964c7cb7f9489decedbb9a,
title = "Experimental validation of a finite element model of a composite tibia",
abstract = "Composite bones are synthetic models made to simulate the mechanical behaviour of human bones. Finite element (FE) models of composite bone can be used to evaluate new and modified designs of joint prostheses and fixation devices. The aim of the current study was to create an FE model of a composite tibia and to validate it against results obtained from a comprehensive set of experiments. For this, 17 strain rosettes were attached to a composite tibia (model 3101, Pacific Research Laboratories, Vashon, Washington, USA). Surface strains and displacements were measured under 13 loading conditions. Two FE models were created on the basis of computed tomography scans. The models differed from each other in the mesh and material properties assigned. The experiments were simulated on them and the results compared with experimental results. The more accurate model was selected on the basis of regression analysis. In general, experimental strain measurements were highly repeatable and compared well with published results. The more accurate model, in which the inner elements representing the foam were assigned isotropic material properties and the elements representing the epoxy layer were assigned transversely isotropic material properties, was able to simulate the mechanical behaviour of the tibia with acceptable accuracy. The regression line for all axial loads combined had a slope of 0.999, an intercept of -6.24 microstrain, and an R2 value of 0.962. The root mean square error as a percentage was 5 per cent.",
author = "Gray, {H. A.} and Zavatsky, {A. B.} and F. Taddei and L. Cristofolini and Gill, {H. S.}",
year = "2007",
doi = "10.1243/09544119JEIM119",
language = "English",
volume = "221",
pages = "315--324",
journal = "Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine",
issn = "0954-4119",
publisher = "Sage Publications",
number = "3",

}

TY - JOUR

T1 - Experimental validation of a finite element model of a composite tibia

AU - Gray, H. A.

AU - Zavatsky, A. B.

AU - Taddei, F.

AU - Cristofolini, L.

AU - Gill, H. S.

PY - 2007

Y1 - 2007

N2 - Composite bones are synthetic models made to simulate the mechanical behaviour of human bones. Finite element (FE) models of composite bone can be used to evaluate new and modified designs of joint prostheses and fixation devices. The aim of the current study was to create an FE model of a composite tibia and to validate it against results obtained from a comprehensive set of experiments. For this, 17 strain rosettes were attached to a composite tibia (model 3101, Pacific Research Laboratories, Vashon, Washington, USA). Surface strains and displacements were measured under 13 loading conditions. Two FE models were created on the basis of computed tomography scans. The models differed from each other in the mesh and material properties assigned. The experiments were simulated on them and the results compared with experimental results. The more accurate model was selected on the basis of regression analysis. In general, experimental strain measurements were highly repeatable and compared well with published results. The more accurate model, in which the inner elements representing the foam were assigned isotropic material properties and the elements representing the epoxy layer were assigned transversely isotropic material properties, was able to simulate the mechanical behaviour of the tibia with acceptable accuracy. The regression line for all axial loads combined had a slope of 0.999, an intercept of -6.24 microstrain, and an R2 value of 0.962. The root mean square error as a percentage was 5 per cent.

AB - Composite bones are synthetic models made to simulate the mechanical behaviour of human bones. Finite element (FE) models of composite bone can be used to evaluate new and modified designs of joint prostheses and fixation devices. The aim of the current study was to create an FE model of a composite tibia and to validate it against results obtained from a comprehensive set of experiments. For this, 17 strain rosettes were attached to a composite tibia (model 3101, Pacific Research Laboratories, Vashon, Washington, USA). Surface strains and displacements were measured under 13 loading conditions. Two FE models were created on the basis of computed tomography scans. The models differed from each other in the mesh and material properties assigned. The experiments were simulated on them and the results compared with experimental results. The more accurate model was selected on the basis of regression analysis. In general, experimental strain measurements were highly repeatable and compared well with published results. The more accurate model, in which the inner elements representing the foam were assigned isotropic material properties and the elements representing the epoxy layer were assigned transversely isotropic material properties, was able to simulate the mechanical behaviour of the tibia with acceptable accuracy. The regression line for all axial loads combined had a slope of 0.999, an intercept of -6.24 microstrain, and an R2 value of 0.962. The root mean square error as a percentage was 5 per cent.

UR - http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=17539586

UR - http://dx.doi.org/10.1243/09544119JEIM119

U2 - 10.1243/09544119JEIM119

DO - 10.1243/09544119JEIM119

M3 - Article

VL - 221

SP - 315

EP - 324

JO - Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine

JF - Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine

SN - 0954-4119

IS - 3

ER -