Experimental Study Comparing EIT in V and Lambda Schemes in Acetylene-Filled HC-PCF

Philip S Light, F Benabid, Francois Couny, G Pearce, David M Bird

Research output: Contribution to conferencePaper

Abstract

We report detailed experimental and theoretical results comparing electromagnetically-induced-transparency obtained in V and Lambda configurations in acetylene-filled-hollow-core PCF. For the same experimental conditions, the EIT in V-scheme shows a stronger peak but larger linewidth.
Original languageEnglish
Pages101-102
Number of pages2
Publication statusPublished - May 2007
EventConference on Lasers and Electro-Optics/Quantum Electronics and Laser Science Conference (CLEO/QELS 2007) - Baltimore, MD, USA United States
Duration: 6 May 200711 May 2007

Conference

ConferenceConference on Lasers and Electro-Optics/Quantum Electronics and Laser Science Conference (CLEO/QELS 2007)
CountryUSA United States
CityBaltimore, MD
Period6/05/0711/05/07

Fingerprint

acetylene
hollow
configurations

Cite this

Light, P. S., Benabid, F., Couny, F., Pearce, G., & Bird, D. M. (2007). Experimental Study Comparing EIT in V and Lambda Schemes in Acetylene-Filled HC-PCF. 101-102. Paper presented at Conference on Lasers and Electro-Optics/Quantum Electronics and Laser Science Conference (CLEO/QELS 2007), Baltimore, MD, USA United States.

Experimental Study Comparing EIT in V and Lambda Schemes in Acetylene-Filled HC-PCF. / Light, Philip S; Benabid, F; Couny, Francois; Pearce, G; Bird, David M.

2007. 101-102 Paper presented at Conference on Lasers and Electro-Optics/Quantum Electronics and Laser Science Conference (CLEO/QELS 2007), Baltimore, MD, USA United States.

Research output: Contribution to conferencePaper

Light, PS, Benabid, F, Couny, F, Pearce, G & Bird, DM 2007, 'Experimental Study Comparing EIT in V and Lambda Schemes in Acetylene-Filled HC-PCF' Paper presented at Conference on Lasers and Electro-Optics/Quantum Electronics and Laser Science Conference (CLEO/QELS 2007), Baltimore, MD, USA United States, 6/05/07 - 11/05/07, pp. 101-102.
Light PS, Benabid F, Couny F, Pearce G, Bird DM. Experimental Study Comparing EIT in V and Lambda Schemes in Acetylene-Filled HC-PCF. 2007. Paper presented at Conference on Lasers and Electro-Optics/Quantum Electronics and Laser Science Conference (CLEO/QELS 2007), Baltimore, MD, USA United States.
Light, Philip S ; Benabid, F ; Couny, Francois ; Pearce, G ; Bird, David M. / Experimental Study Comparing EIT in V and Lambda Schemes in Acetylene-Filled HC-PCF. Paper presented at Conference on Lasers and Electro-Optics/Quantum Electronics and Laser Science Conference (CLEO/QELS 2007), Baltimore, MD, USA United States.2 p.
@conference{1639958a529b44f68da41915559795c9,
title = "Experimental Study Comparing EIT in V and Lambda Schemes in Acetylene-Filled HC-PCF",
abstract = "We report detailed experimental and theoretical results comparing electromagnetically-induced-transparency obtained in V and Lambda configurations in acetylene-filled-hollow-core PCF. For the same experimental conditions, the EIT in V-scheme shows a stronger peak but larger linewidth.",
author = "Light, {Philip S} and F Benabid and Francois Couny and G Pearce and Bird, {David M}",
year = "2007",
month = "5",
language = "English",
pages = "101--102",
note = "Conference on Lasers and Electro-Optics/Quantum Electronics and Laser Science Conference (CLEO/QELS 2007) ; Conference date: 06-05-2007 Through 11-05-2007",

}

TY - CONF

T1 - Experimental Study Comparing EIT in V and Lambda Schemes in Acetylene-Filled HC-PCF

AU - Light, Philip S

AU - Benabid, F

AU - Couny, Francois

AU - Pearce, G

AU - Bird, David M

PY - 2007/5

Y1 - 2007/5

N2 - We report detailed experimental and theoretical results comparing electromagnetically-induced-transparency obtained in V and Lambda configurations in acetylene-filled-hollow-core PCF. For the same experimental conditions, the EIT in V-scheme shows a stronger peak but larger linewidth.

AB - We report detailed experimental and theoretical results comparing electromagnetically-induced-transparency obtained in V and Lambda configurations in acetylene-filled-hollow-core PCF. For the same experimental conditions, the EIT in V-scheme shows a stronger peak but larger linewidth.

M3 - Paper

SP - 101

EP - 102

ER -