Body weight supported robotic-assisted devices are normally used in gait rehabilitation of neurologically impaired persons but also have potential for application in cardiopulmonary rehabilitation. In this paper, a method of estimating and controlling the rate of active work done during supported stepping is proposed and experimentally validated through ambulation of three subjects with a spinal cord injury. The estimation and feedback scheme enabled work rates to be produced in close agreement to reference values. The efficacy of the proposed control scheme will facilitate the use of the technology in cardiopulmonary training and testing protocols.
Original languageEnglish
Pages (from-to)322-328
Number of pages7
JournalControl Engineering Practice
Volume17
Issue number2
DOIs
Publication statusPublished - 2 Feb 2009

Cite this

Estimation and volitional feedback control of active work rate during robot-assisted gait. / Pennycott, A; Hunt, K. J.; Jack, L. P.; Perret, C; Kakebeeke, T. H.

In: Control Engineering Practice, Vol. 17, No. 2, 02.02.2009, p. 322-328.

Research output: Contribution to journalArticle

Pennycott, A ; Hunt, K. J. ; Jack, L. P. ; Perret, C ; Kakebeeke, T. H. / Estimation and volitional feedback control of active work rate during robot-assisted gait. In: Control Engineering Practice. 2009 ; Vol. 17, No. 2. pp. 322-328.
@article{b3121ee8debd43fcab6fbfd5573f326b,
title = "Estimation and volitional feedback control of active work rate during robot-assisted gait",
abstract = "Body weight supported robotic-assisted devices are normally used in gait rehabilitation of neurologically impaired persons but also have potential for application in cardiopulmonary rehabilitation. In this paper, a method of estimating and controlling the rate of active work done during supported stepping is proposed and experimentally validated through ambulation of three subjects with a spinal cord injury. The estimation and feedback scheme enabled work rates to be produced in close agreement to reference values. The efficacy of the proposed control scheme will facilitate the use of the technology in cardiopulmonary training and testing protocols.",
author = "A Pennycott and Hunt, {K. J.} and Jack, {L. P.} and C Perret and Kakebeeke, {T. H.}",
year = "2009",
month = "2",
day = "2",
doi = "10.1016/j.conengprac.2008.09.011",
language = "English",
volume = "17",
pages = "322--328",
journal = "Control Engineering Practice",
issn = "0967-0661",
publisher = "Elsevier",
number = "2",

}

TY - JOUR

T1 - Estimation and volitional feedback control of active work rate during robot-assisted gait

AU - Pennycott, A

AU - Hunt, K. J.

AU - Jack, L. P.

AU - Perret, C

AU - Kakebeeke, T. H.

PY - 2009/2/2

Y1 - 2009/2/2

N2 - Body weight supported robotic-assisted devices are normally used in gait rehabilitation of neurologically impaired persons but also have potential for application in cardiopulmonary rehabilitation. In this paper, a method of estimating and controlling the rate of active work done during supported stepping is proposed and experimentally validated through ambulation of three subjects with a spinal cord injury. The estimation and feedback scheme enabled work rates to be produced in close agreement to reference values. The efficacy of the proposed control scheme will facilitate the use of the technology in cardiopulmonary training and testing protocols.

AB - Body weight supported robotic-assisted devices are normally used in gait rehabilitation of neurologically impaired persons but also have potential for application in cardiopulmonary rehabilitation. In this paper, a method of estimating and controlling the rate of active work done during supported stepping is proposed and experimentally validated through ambulation of three subjects with a spinal cord injury. The estimation and feedback scheme enabled work rates to be produced in close agreement to reference values. The efficacy of the proposed control scheme will facilitate the use of the technology in cardiopulmonary training and testing protocols.

U2 - 10.1016/j.conengprac.2008.09.011

DO - 10.1016/j.conengprac.2008.09.011

M3 - Article

VL - 17

SP - 322

EP - 328

JO - Control Engineering Practice

JF - Control Engineering Practice

SN - 0967-0661

IS - 2