Abstract

Objectives: This work aimed to elucidate the role of electroosmosis during trans-nail iontophoresis.

Methods: Passive and iontophoretic experiments were performed after short hydration (10-15 min) of human nail tips. The electroosmotic fluxes of mannitol were determined during anodal and cathodal iontophoresis and at different pH values. Passive controls were also carried out. Four sets of experiments were performed: (a) three anodal delivery experiments using different nails, at pH 4.0, 5.0 and 7.4, (b) one anodal delivery experiment that kept the same nails across two pH stages, (c) one experiment, comprising an anodal delivery stage (pH 4 and 7.4) followed by a cathodal delivery stage (pH 7.4 and 4), which kept the same nails across the different polarities and pH stages, and (d) a passive experiment keeping the same nails across different pH values (4 and 7.4).

Results: The fluxes of mannitol measured were very variable and little difference between passive and electroosmotic transport was observed. Cathodal and anodal fluxes were not always significantly different. Experiments which minimised internail variability suggested that the nails were negatively charged at physiological pH, and that this negative charge was lost at pH 4.

Conclusions: These results suggest a modest and highly variable contribution of electroosmosis to the iontophoretic transungual flux.

Original languageEnglish
Pages (from-to)721-729
Number of pages9
JournalJournal of Pharmacy and Pharmacology
Volume62
Issue number6
DOIs
Publication statusPublished - Jun 2010

Fingerprint

Iontophoresis
Mannitol
Nails
Electroosmosis

Keywords

  • nail
  • iontophoresis
  • permselectivity
  • electroosmosis
  • mannitol

Cite this

Electroosmotic transport of mannitol across human nail during constant current iontophoresis. / Dutet, Julie; Delgado-Charro, M B.

In: Journal of Pharmacy and Pharmacology, Vol. 62, No. 6, 06.2010, p. 721-729.

Research output: Contribution to journalArticle

@article{0d91f399d3e2471da2765443741587f4,
title = "Electroosmotic transport of mannitol across human nail during constant current iontophoresis",
abstract = "Objectives: This work aimed to elucidate the role of electroosmosis during trans-nail iontophoresis. Methods: Passive and iontophoretic experiments were performed after short hydration (10-15 min) of human nail tips. The electroosmotic fluxes of mannitol were determined during anodal and cathodal iontophoresis and at different pH values. Passive controls were also carried out. Four sets of experiments were performed: (a) three anodal delivery experiments using different nails, at pH 4.0, 5.0 and 7.4, (b) one anodal delivery experiment that kept the same nails across two pH stages, (c) one experiment, comprising an anodal delivery stage (pH 4 and 7.4) followed by a cathodal delivery stage (pH 7.4 and 4), which kept the same nails across the different polarities and pH stages, and (d) a passive experiment keeping the same nails across different pH values (4 and 7.4). Results: The fluxes of mannitol measured were very variable and little difference between passive and electroosmotic transport was observed. Cathodal and anodal fluxes were not always significantly different. Experiments which minimised internail variability suggested that the nails were negatively charged at physiological pH, and that this negative charge was lost at pH 4. Conclusions: These results suggest a modest and highly variable contribution of electroosmosis to the iontophoretic transungual flux.",
keywords = "nail, iontophoresis, permselectivity, electroosmosis, mannitol",
author = "Julie Dutet and Delgado-Charro, {M B}",
year = "2010",
month = "6",
doi = "10.1211/jpp/62.06.0008",
language = "English",
volume = "62",
pages = "721--729",
journal = "Journal of Pharmacy and Pharmacology",
issn = "0022-3573",
publisher = "Pharmaceutical Press",
number = "6",

}

TY - JOUR

T1 - Electroosmotic transport of mannitol across human nail during constant current iontophoresis

AU - Dutet, Julie

AU - Delgado-Charro, M B

PY - 2010/6

Y1 - 2010/6

N2 - Objectives: This work aimed to elucidate the role of electroosmosis during trans-nail iontophoresis. Methods: Passive and iontophoretic experiments were performed after short hydration (10-15 min) of human nail tips. The electroosmotic fluxes of mannitol were determined during anodal and cathodal iontophoresis and at different pH values. Passive controls were also carried out. Four sets of experiments were performed: (a) three anodal delivery experiments using different nails, at pH 4.0, 5.0 and 7.4, (b) one anodal delivery experiment that kept the same nails across two pH stages, (c) one experiment, comprising an anodal delivery stage (pH 4 and 7.4) followed by a cathodal delivery stage (pH 7.4 and 4), which kept the same nails across the different polarities and pH stages, and (d) a passive experiment keeping the same nails across different pH values (4 and 7.4). Results: The fluxes of mannitol measured were very variable and little difference between passive and electroosmotic transport was observed. Cathodal and anodal fluxes were not always significantly different. Experiments which minimised internail variability suggested that the nails were negatively charged at physiological pH, and that this negative charge was lost at pH 4. Conclusions: These results suggest a modest and highly variable contribution of electroosmosis to the iontophoretic transungual flux.

AB - Objectives: This work aimed to elucidate the role of electroosmosis during trans-nail iontophoresis. Methods: Passive and iontophoretic experiments were performed after short hydration (10-15 min) of human nail tips. The electroosmotic fluxes of mannitol were determined during anodal and cathodal iontophoresis and at different pH values. Passive controls were also carried out. Four sets of experiments were performed: (a) three anodal delivery experiments using different nails, at pH 4.0, 5.0 and 7.4, (b) one anodal delivery experiment that kept the same nails across two pH stages, (c) one experiment, comprising an anodal delivery stage (pH 4 and 7.4) followed by a cathodal delivery stage (pH 7.4 and 4), which kept the same nails across the different polarities and pH stages, and (d) a passive experiment keeping the same nails across different pH values (4 and 7.4). Results: The fluxes of mannitol measured were very variable and little difference between passive and electroosmotic transport was observed. Cathodal and anodal fluxes were not always significantly different. Experiments which minimised internail variability suggested that the nails were negatively charged at physiological pH, and that this negative charge was lost at pH 4. Conclusions: These results suggest a modest and highly variable contribution of electroosmosis to the iontophoretic transungual flux.

KW - nail

KW - iontophoresis

KW - permselectivity

KW - electroosmosis

KW - mannitol

UR - http://www.scopus.com/inward/record.url?scp=77953594289&partnerID=8YFLogxK

UR - http://www3.interscience.wiley.com/journal/123510014/abstract

U2 - 10.1211/jpp/62.06.0008

DO - 10.1211/jpp/62.06.0008

M3 - Article

VL - 62

SP - 721

EP - 729

JO - Journal of Pharmacy and Pharmacology

JF - Journal of Pharmacy and Pharmacology

SN - 0022-3573

IS - 6

ER -