Development of a model-based roentgen stereophotogrammetric analysis system to measure polyethylene wear in unicompartmental arthroplasty

D. J. Simpson, B. J. Kendrick, B. L. Kaptein, A. J. Price, D. W. Murray, H. S. Gill

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

One of the most important causes of failure in unicompartmental knee replacement (UKR) is polyethylene wear. The aim of this study was to develop and assess a novel Roentgen stereophotogrammetric analysis (RSA)-based method for the measurement of linear wear suitable for UKR. Model-based RSA was used to estimate the linear wear of polyethylene bearings in UKR. A phantom was used to validate the method using in vitro measured bearing thicknesses and the linear wear of ten control bearings was estimated in vivo. Computer aided design (CAD) models for the UKRs were used in the model-based RSA system. There was no statistically significant difference between the estimated and measured bearing thicknesses using the CAD models (p = 0.386). The precision of the linear wear measurement, expressed as the standard deviation of the difference between the estimated and measured bearing thickness was 0.163 mm. The bias (mean difference) was 0.030 mm. The use of RSA to measure in vivo wear in a UKR has been shown to be accurate in a phantom, and has been verified with in vivo measured controls. The technique does not require surgical implantation of marker balls and can be used retrospectively.
Original languageEnglish
Pages (from-to)1235-1243
Number of pages9
JournalProceedings of the Institution of Mechanical Engineers, Part H - Journal of Engineering in Medicine
Volume224
Issue number11
DOIs
Publication statusPublished - 1 Nov 2010

Fingerprint

Bearings (structural)
Arthroplasty
Knee prostheses
Polyethylenes
Wear of materials
Computer aided design

Cite this

Development of a model-based roentgen stereophotogrammetric analysis system to measure polyethylene wear in unicompartmental arthroplasty. / Simpson, D. J.; Kendrick, B. J.; Kaptein, B. L.; Price, A. J.; Murray, D. W.; Gill, H. S.

In: Proceedings of the Institution of Mechanical Engineers, Part H - Journal of Engineering in Medicine, Vol. 224, No. 11, 01.11.2010, p. 1235-1243.

Research output: Contribution to journalArticle

@article{e4eece70ba364dd6951ef377b5cdaf7d,
title = "Development of a model-based roentgen stereophotogrammetric analysis system to measure polyethylene wear in unicompartmental arthroplasty",
abstract = "One of the most important causes of failure in unicompartmental knee replacement (UKR) is polyethylene wear. The aim of this study was to develop and assess a novel Roentgen stereophotogrammetric analysis (RSA)-based method for the measurement of linear wear suitable for UKR. Model-based RSA was used to estimate the linear wear of polyethylene bearings in UKR. A phantom was used to validate the method using in vitro measured bearing thicknesses and the linear wear of ten control bearings was estimated in vivo. Computer aided design (CAD) models for the UKRs were used in the model-based RSA system. There was no statistically significant difference between the estimated and measured bearing thicknesses using the CAD models (p = 0.386). The precision of the linear wear measurement, expressed as the standard deviation of the difference between the estimated and measured bearing thickness was 0.163 mm. The bias (mean difference) was 0.030 mm. The use of RSA to measure in vivo wear in a UKR has been shown to be accurate in a phantom, and has been verified with in vivo measured controls. The technique does not require surgical implantation of marker balls and can be used retrospectively.",
author = "Simpson, {D. J.} and Kendrick, {B. J.} and Kaptein, {B. L.} and Price, {A. J.} and Murray, {D. W.} and Gill, {H. S.}",
year = "2010",
month = "11",
day = "1",
doi = "10.1243/09544119JEIM812",
language = "English",
volume = "224",
pages = "1235--1243",
journal = "Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine",
issn = "0954-4119",
publisher = "Sage Publications",
number = "11",

}

TY - JOUR

T1 - Development of a model-based roentgen stereophotogrammetric analysis system to measure polyethylene wear in unicompartmental arthroplasty

AU - Simpson, D. J.

AU - Kendrick, B. J.

AU - Kaptein, B. L.

AU - Price, A. J.

AU - Murray, D. W.

AU - Gill, H. S.

PY - 2010/11/1

Y1 - 2010/11/1

N2 - One of the most important causes of failure in unicompartmental knee replacement (UKR) is polyethylene wear. The aim of this study was to develop and assess a novel Roentgen stereophotogrammetric analysis (RSA)-based method for the measurement of linear wear suitable for UKR. Model-based RSA was used to estimate the linear wear of polyethylene bearings in UKR. A phantom was used to validate the method using in vitro measured bearing thicknesses and the linear wear of ten control bearings was estimated in vivo. Computer aided design (CAD) models for the UKRs were used in the model-based RSA system. There was no statistically significant difference between the estimated and measured bearing thicknesses using the CAD models (p = 0.386). The precision of the linear wear measurement, expressed as the standard deviation of the difference between the estimated and measured bearing thickness was 0.163 mm. The bias (mean difference) was 0.030 mm. The use of RSA to measure in vivo wear in a UKR has been shown to be accurate in a phantom, and has been verified with in vivo measured controls. The technique does not require surgical implantation of marker balls and can be used retrospectively.

AB - One of the most important causes of failure in unicompartmental knee replacement (UKR) is polyethylene wear. The aim of this study was to develop and assess a novel Roentgen stereophotogrammetric analysis (RSA)-based method for the measurement of linear wear suitable for UKR. Model-based RSA was used to estimate the linear wear of polyethylene bearings in UKR. A phantom was used to validate the method using in vitro measured bearing thicknesses and the linear wear of ten control bearings was estimated in vivo. Computer aided design (CAD) models for the UKRs were used in the model-based RSA system. There was no statistically significant difference between the estimated and measured bearing thicknesses using the CAD models (p = 0.386). The precision of the linear wear measurement, expressed as the standard deviation of the difference between the estimated and measured bearing thickness was 0.163 mm. The bias (mean difference) was 0.030 mm. The use of RSA to measure in vivo wear in a UKR has been shown to be accurate in a phantom, and has been verified with in vivo measured controls. The technique does not require surgical implantation of marker balls and can be used retrospectively.

UR - http://www.scopus.com/inward/record.url?scp=78349262220&partnerID=8YFLogxK

UR - http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=21218686

UR - http://dx.doi.org/10.1243/09544119JEIM812

U2 - 10.1243/09544119JEIM812

DO - 10.1243/09544119JEIM812

M3 - Article

VL - 224

SP - 1235

EP - 1243

JO - Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine

JF - Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine

SN - 0954-4119

IS - 11

ER -