TY - JOUR
T1 - Development of a highly-sensitive multi-plex assay using monoclonal antibodies for the simultaneous measurement of kappa and lambda immunoglobulin free light chains in serum and urine
AU - Campbell, John P.
AU - Wang, Yanyun
AU - Cobbold, Mark
AU - Goodall, Margaret
AU - Bonney, Sarah L.
AU - Chamba, Anita
AU - Birtwistle, Jane
AU - Plant, Timothy
AU - Afzal, Zaheer
AU - Jefferis, Roy
AU - Drayson, Mark T.
N1 - Copyright © 2013 Elsevier B.V. All rights reserved.
PY - 2013/5/31
Y1 - 2013/5/31
N2 - Monoclonal κ and λ immunoglobulin free light chain (FLC) paraproteins in serum and urine are important markers in the diagnosis and monitoring of B cell dyscrasias. Current nephelometric and turbidimetric methods that use sheep polyclonal antisera to quantify serum FLC have a number of well-observed limitations. In this report, we describe an improved method using specific mouse anti-human FLC monoclonal antibodies (mAbs). Anti-κ and anti-λ FLC mAbs were, separately, covalently coupled to polystyrene Xmap® beads and assayed, simultaneously, in a multi-plex format by Luminex® (mAb assay). The mAbs displayed no cross-reactivity to bound LC, the alternate LC type, or other human proteins and had improved sensitivity and specificity over immunofixation electrophoresis (IFE) and Freelite™. The assay gives good linearity and sensitivity (<1 mg/L), and the competitive inhibition format gave a broad calibration curve up to 437.5 mg/L and prevented anomalous results for samples in antigen excess i.e. high FLC levels. The mAbs displayed good concordance with Freelite™ for the quantitation of normal polyclonal FLC in plasma from healthy donors (n=249). The mAb assay identified all monoclonal FLC in serum from consecutive patient samples (n=1000; 50.1% with monoclonal paraprotein by serum IFE), and all FLC in a large cohort of urine samples tested for Bence Jones proteins (n=13090; 22.8% with monoclonal κ, 9.0% with monoclonal λ, and 0.8% with poly LC detected by urine IFE). Importantly this shows that the mAbs are at least close to the ideal of detecting FLC from all patients and neoplastic plasma cell clones. Given the overall effectiveness of the anti-FLC mAbs, further clinical validation is now warranted on serial samples from a range of patients with B cell disorders. Use of these mAbs on other assay platforms should also be investigated.
AB - Monoclonal κ and λ immunoglobulin free light chain (FLC) paraproteins in serum and urine are important markers in the diagnosis and monitoring of B cell dyscrasias. Current nephelometric and turbidimetric methods that use sheep polyclonal antisera to quantify serum FLC have a number of well-observed limitations. In this report, we describe an improved method using specific mouse anti-human FLC monoclonal antibodies (mAbs). Anti-κ and anti-λ FLC mAbs were, separately, covalently coupled to polystyrene Xmap® beads and assayed, simultaneously, in a multi-plex format by Luminex® (mAb assay). The mAbs displayed no cross-reactivity to bound LC, the alternate LC type, or other human proteins and had improved sensitivity and specificity over immunofixation electrophoresis (IFE) and Freelite™. The assay gives good linearity and sensitivity (<1 mg/L), and the competitive inhibition format gave a broad calibration curve up to 437.5 mg/L and prevented anomalous results for samples in antigen excess i.e. high FLC levels. The mAbs displayed good concordance with Freelite™ for the quantitation of normal polyclonal FLC in plasma from healthy donors (n=249). The mAb assay identified all monoclonal FLC in serum from consecutive patient samples (n=1000; 50.1% with monoclonal paraprotein by serum IFE), and all FLC in a large cohort of urine samples tested for Bence Jones proteins (n=13090; 22.8% with monoclonal κ, 9.0% with monoclonal λ, and 0.8% with poly LC detected by urine IFE). Importantly this shows that the mAbs are at least close to the ideal of detecting FLC from all patients and neoplastic plasma cell clones. Given the overall effectiveness of the anti-FLC mAbs, further clinical validation is now warranted on serial samples from a range of patients with B cell disorders. Use of these mAbs on other assay platforms should also be investigated.
KW - Animals
KW - Antibodies, Monoclonal
KW - Antibody Specificity
KW - Binding, Competitive
KW - Biomarkers, Tumor
KW - Calibration
KW - Case-Control Studies
KW - Cross Reactions
KW - Humans
KW - Immunoassay
KW - Immunoglobulin kappa-Chains
KW - Immunoglobulin lambda-Chains
KW - Linear Models
KW - Mice
KW - Mice, Inbred BALB C
KW - Multiple Myeloma
KW - Predictive Value of Tests
KW - Reference Standards
KW - Reproducibility of Results
KW - Sensitivity and Specificity
UR - http://dx.doi.org/10.1016/j.jim.2013.01.014
UR - http://dx.doi.org/10.1016/j.jim.2013.01.014
U2 - 10.1016/j.jim.2013.01.014
DO - 10.1016/j.jim.2013.01.014
M3 - Article
C2 - 23388695
VL - 391
SP - 1
EP - 13
JO - Journal of Immunological Methods
JF - Journal of Immunological Methods
SN - 0022-1759
IS - 1-2
ER -