Capacitance-digital and impedance converter as electrical tomography measurement system for biological tissue

Mila Izzatul Ikhsanti, Rana Bouzida, Sastra Kusuma Wijaya, A Rohmadi, Imamul Muttakin, Warsito P. Taruno

Abstract

This research aims to explore the feasibility of capacitance-digital converter and impedance converter for measurement module in electrical capacitance tomography (ECT) system. ECT sensor used was a cylindrical sensor having 8 electrodes. Absolute capacitance measurement system based on Sigma Delta Capacitance-to-Digital-Converter AD7746 has been shown to produce measurement with high resolution. Whereas, capacitance measurement with wide range of frequency is possible using Impedance Converter AD5933. Comparison of measurement accuracy by both AD7746 and AD5933 with reference of LCR meter was evaluated. Biological matters represented in water and oil were treated as object reconstructed into image using linear back projection (LBP) algorithm.

Original languageEnglish
Title of host publicationAIP Conference Proceedings
PublisherAIP Publishing
Volume1817
Edition1
ISBN (Electronic)9780735414853
DOIs
StatePublished - 21 Feb 2017
Event1st International Symposium of Biomedical Engineering: Biomedical Engineering's Recent Progress in Biomaterials, Drugs Development, and Medical Devices, ISBE 2016 - Depok City, Indonesia

Conference

Conference1st International Symposium of Biomedical Engineering: Biomedical Engineering's Recent Progress in Biomaterials, Drugs Development, and Medical Devices, ISBE 2016
CountryIndonesia
CityDepok City
Period31/05/161/06/16

Fingerprint

Capacitance
Tomography
Capacitance measurement
Sensors
Tissue
Electrodes
Water

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

Ikhsanti, M. I., Bouzida, R., Wijaya, S. K., Rohmadi, A., Muttakin, I., & Taruno, W. P. (2017). Capacitance-digital and impedance converter as electrical tomography measurement system for biological tissue. In AIP Conference Proceedings (1 ed., Vol. 1817). [040013] AIP Publishing. DOI: 10.1063/1.4976798

Capacitance-digital and impedance converter as electrical tomography measurement system for biological tissue. / Ikhsanti, Mila Izzatul; Bouzida, Rana; Wijaya, Sastra Kusuma; Rohmadi, A; Muttakin, Imamul; Taruno, Warsito P.

AIP Conference Proceedings. Vol. 1817 1. ed. AIP Publishing, 2017. 040013.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Ikhsanti, MI, Bouzida, R, Wijaya, SK, Rohmadi, A, Muttakin, I & Taruno, WP 2017, Capacitance-digital and impedance converter as electrical tomography measurement system for biological tissue. in AIP Conference Proceedings. 1 edn, vol. 1817, 040013, AIP Publishing, 1st International Symposium of Biomedical Engineering: Biomedical Engineering's Recent Progress in Biomaterials, Drugs Development, and Medical Devices, ISBE 2016, Depok City, Indonesia, 31-1 June. DOI: 10.1063/1.4976798
Ikhsanti MI, Bouzida R, Wijaya SK, Rohmadi A, Muttakin I, Taruno WP. Capacitance-digital and impedance converter as electrical tomography measurement system for biological tissue. In AIP Conference Proceedings. 1 ed. Vol. 1817. AIP Publishing. 2017. 040013. Available from, DOI: 10.1063/1.4976798

Ikhsanti, Mila Izzatul; Bouzida, Rana; Wijaya, Sastra Kusuma; Rohmadi, A; Muttakin, Imamul; Taruno, Warsito P. / Capacitance-digital and impedance converter as electrical tomography measurement system for biological tissue.

AIP Conference Proceedings. Vol. 1817 1. ed. AIP Publishing, 2017. 040013.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

@inbook{a541e2f2e04144a789d4367c37681e4b,
title = "Capacitance-digital and impedance converter as electrical tomography measurement system for biological tissue",
abstract = "This research aims to explore the feasibility of capacitance-digital converter and impedance converter for measurement module in electrical capacitance tomography (ECT) system. ECT sensor used was a cylindrical sensor having 8 electrodes. Absolute capacitance measurement system based on Sigma Delta Capacitance-to-Digital-Converter AD7746 has been shown to produce measurement with high resolution. Whereas, capacitance measurement with wide range of frequency is possible using Impedance Converter AD5933. Comparison of measurement accuracy by both AD7746 and AD5933 with reference of LCR meter was evaluated. Biological matters represented in water and oil were treated as object reconstructed into image using linear back projection (LBP) algorithm.",
author = "Ikhsanti, {Mila Izzatul} and Rana Bouzida and Wijaya, {Sastra Kusuma} and A Rohmadi and Imamul Muttakin and Taruno, {Warsito P.}",
year = "2017",
month = "2",
doi = "10.1063/1.4976798",
volume = "1817",
booktitle = "AIP Conference Proceedings",
publisher = "AIP Publishing",
address = "USA United States",
edition = "1",

}

TY - CHAP

T1 - Capacitance-digital and impedance converter as electrical tomography measurement system for biological tissue

AU - Ikhsanti,Mila Izzatul

AU - Bouzida,Rana

AU - Wijaya,Sastra Kusuma

AU - Rohmadi,A

AU - Muttakin,Imamul

AU - Taruno,Warsito P.

PY - 2017/2/21

Y1 - 2017/2/21

N2 - This research aims to explore the feasibility of capacitance-digital converter and impedance converter for measurement module in electrical capacitance tomography (ECT) system. ECT sensor used was a cylindrical sensor having 8 electrodes. Absolute capacitance measurement system based on Sigma Delta Capacitance-to-Digital-Converter AD7746 has been shown to produce measurement with high resolution. Whereas, capacitance measurement with wide range of frequency is possible using Impedance Converter AD5933. Comparison of measurement accuracy by both AD7746 and AD5933 with reference of LCR meter was evaluated. Biological matters represented in water and oil were treated as object reconstructed into image using linear back projection (LBP) algorithm.

AB - This research aims to explore the feasibility of capacitance-digital converter and impedance converter for measurement module in electrical capacitance tomography (ECT) system. ECT sensor used was a cylindrical sensor having 8 electrodes. Absolute capacitance measurement system based on Sigma Delta Capacitance-to-Digital-Converter AD7746 has been shown to produce measurement with high resolution. Whereas, capacitance measurement with wide range of frequency is possible using Impedance Converter AD5933. Comparison of measurement accuracy by both AD7746 and AD5933 with reference of LCR meter was evaluated. Biological matters represented in water and oil were treated as object reconstructed into image using linear back projection (LBP) algorithm.

UR - http://www.scopus.com/inward/record.url?scp=85015988502&partnerID=8YFLogxK

U2 - 10.1063/1.4976798

DO - 10.1063/1.4976798

M3 - Conference contribution

VL - 1817

BT - AIP Conference Proceedings

PB - AIP Publishing

ER -