Protein chips have demonstrated to be a sensitive and low cost solution to identify and detect tumor markers. However, efficient multiparametric analysis remains a challenge due to protein variability. Crucial parameters are the design of stable and reproducible surfaces which maintain biological activity of immobilized proteins. These parameters relate to surface chemistry and to immobilization conditions (printing buffers, washing etc.). In this study, we have developed and characterized various surface chemistries for the immobilization of anti-tumor antigen antibodies onto microstructured glass slides. The effect of surface properties and antibody immobilization conditions were evaluated for the detection of tumor antigens involved in colorectal cancer. Experimental results demonstrated that the biological activities of the immobilized antibodies were dependent on the surface chemistry and on the immobilization procedure. Optimal immobilization conditions were different for each antibody. Limit of detection in tumor antigen as low as 10 pM can reach under optimized conditions. Our 3D microstructured chip offers the possibility to implement a customized multiplex immunoassay combining optimal immobilization condition for each antibody-antigen system on the same chip.
Original languageEnglish
Pages (from-to)22-28
Number of pages7
JournalSensors and Actuators B: Chemical
Volume175
DOIs
Publication statusPublished - Dec 2012

Fingerprint

immunoassay
biomarkers
Tumor Biomarkers
immobilization
Antibodies
Antigens
antibodies
Neoplasm Antigens
Surface chemistry
cancer
chips
antigens
proteins
Proteins
tumors
Tumors
Bioactivity
chemistry
Immobilized Proteins
Immobilized Antibodies

Keywords

  • Cancer biomarkers
  • Diagnosis
  • Immobilization
  • Protein chip
  • Surface chemistry

Cite this

Cancer biomarkers detection using 3D microstructured protein chip : Implementation of customized multiplex immunoassay. / Yang, Z.; Chevolot, Y.; Ataman-Önal, Y.; Choquet-Kastylevsky, G.; Souteyrand, E.; Laurenceau, E.

In: Sensors and Actuators B: Chemical, Vol. 175, 12.2012, p. 22-28.

Research output: Contribution to journalArticle

Yang, Z. ; Chevolot, Y. ; Ataman-Önal, Y. ; Choquet-Kastylevsky, G. ; Souteyrand, E. ; Laurenceau, E. / Cancer biomarkers detection using 3D microstructured protein chip : Implementation of customized multiplex immunoassay. In: Sensors and Actuators B: Chemical. 2012 ; Vol. 175. pp. 22-28.
@article{9fd90b19475e4e3b9d5031c694a7bd50,
title = "Cancer biomarkers detection using 3D microstructured protein chip: Implementation of customized multiplex immunoassay",
abstract = "Protein chips have demonstrated to be a sensitive and low cost solution to identify and detect tumor markers. However, efficient multiparametric analysis remains a challenge due to protein variability. Crucial parameters are the design of stable and reproducible surfaces which maintain biological activity of immobilized proteins. These parameters relate to surface chemistry and to immobilization conditions (printing buffers, washing etc.). In this study, we have developed and characterized various surface chemistries for the immobilization of anti-tumor antigen antibodies onto microstructured glass slides. The effect of surface properties and antibody immobilization conditions were evaluated for the detection of tumor antigens involved in colorectal cancer. Experimental results demonstrated that the biological activities of the immobilized antibodies were dependent on the surface chemistry and on the immobilization procedure. Optimal immobilization conditions were different for each antibody. Limit of detection in tumor antigen as low as 10 pM can reach under optimized conditions. Our 3D microstructured chip offers the possibility to implement a customized multiplex immunoassay combining optimal immobilization condition for each antibody-antigen system on the same chip.",
keywords = "Cancer biomarkers, Diagnosis, Immobilization, Protein chip, Surface chemistry",
author = "Z. Yang and Y. Chevolot and Y. Ataman-{\"O}nal and G. Choquet-Kastylevsky and E. Souteyrand and E. Laurenceau",
note = "Cited By (since 1996):4 Export Date: 14 November 2013 Source: Scopus",
year = "2012",
month = "12",
doi = "10.1016/j.snb.2011.11.055",
language = "English",
volume = "175",
pages = "22--28",
journal = "Sensors and Actuators B: Chemical",
issn = "0925-4005",
publisher = "Elsevier",

}

TY - JOUR

T1 - Cancer biomarkers detection using 3D microstructured protein chip

T2 - Implementation of customized multiplex immunoassay

AU - Yang, Z.

AU - Chevolot, Y.

AU - Ataman-Önal, Y.

AU - Choquet-Kastylevsky, G.

AU - Souteyrand, E.

AU - Laurenceau, E.

N1 - Cited By (since 1996):4 Export Date: 14 November 2013 Source: Scopus

PY - 2012/12

Y1 - 2012/12

N2 - Protein chips have demonstrated to be a sensitive and low cost solution to identify and detect tumor markers. However, efficient multiparametric analysis remains a challenge due to protein variability. Crucial parameters are the design of stable and reproducible surfaces which maintain biological activity of immobilized proteins. These parameters relate to surface chemistry and to immobilization conditions (printing buffers, washing etc.). In this study, we have developed and characterized various surface chemistries for the immobilization of anti-tumor antigen antibodies onto microstructured glass slides. The effect of surface properties and antibody immobilization conditions were evaluated for the detection of tumor antigens involved in colorectal cancer. Experimental results demonstrated that the biological activities of the immobilized antibodies were dependent on the surface chemistry and on the immobilization procedure. Optimal immobilization conditions were different for each antibody. Limit of detection in tumor antigen as low as 10 pM can reach under optimized conditions. Our 3D microstructured chip offers the possibility to implement a customized multiplex immunoassay combining optimal immobilization condition for each antibody-antigen system on the same chip.

AB - Protein chips have demonstrated to be a sensitive and low cost solution to identify and detect tumor markers. However, efficient multiparametric analysis remains a challenge due to protein variability. Crucial parameters are the design of stable and reproducible surfaces which maintain biological activity of immobilized proteins. These parameters relate to surface chemistry and to immobilization conditions (printing buffers, washing etc.). In this study, we have developed and characterized various surface chemistries for the immobilization of anti-tumor antigen antibodies onto microstructured glass slides. The effect of surface properties and antibody immobilization conditions were evaluated for the detection of tumor antigens involved in colorectal cancer. Experimental results demonstrated that the biological activities of the immobilized antibodies were dependent on the surface chemistry and on the immobilization procedure. Optimal immobilization conditions were different for each antibody. Limit of detection in tumor antigen as low as 10 pM can reach under optimized conditions. Our 3D microstructured chip offers the possibility to implement a customized multiplex immunoassay combining optimal immobilization condition for each antibody-antigen system on the same chip.

KW - Cancer biomarkers

KW - Diagnosis

KW - Immobilization

KW - Protein chip

KW - Surface chemistry

UR - http://www.scopus.com/inward/record.url?scp=84870246787&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/record.url?eid=2-s2.0-84870246787&partnerID=40&md5=2cf1a5a0e4d1d7173c311cb998bd1c23

UR - http://dx.doi.org/10.1016/j.snb.2011.11.055

U2 - 10.1016/j.snb.2011.11.055

DO - 10.1016/j.snb.2011.11.055

M3 - Article

VL - 175

SP - 22

EP - 28

JO - Sensors and Actuators B: Chemical

JF - Sensors and Actuators B: Chemical

SN - 0925-4005

ER -