Biomechanical evaluation of double-stranded knot configurations in high-strength sutures and tapes

Mehar Dhillon, Tatjana Pastor, Ivan Zderic, Sarina Hebsacker, Björn Christian Link, James Fletcher, R. Geoff Richards, Boyko Gueorguiev, Torsten Pastor

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose
Recently, a new dynamic high-strength suture (DC) was introduced, also available in tape form (DT), featuring a salt-infused silicone core attracting water in a fluid environment to preserve tissue approximation. The aims of this study were to (1) assess the influence of securing throw number on knot security of two double-stranded knot configurations (Cow-hitch and Nice-knot) tied with either dynamic (DC and DT) or conventional (FW and ST) high-strength sutures and tapes, and (2) compare the ultimate force and knot slippage of the novel dynamic versus conventional sutures and tapes when used with their minimal number of needed securing throws.

Methods
Seven specimens of each FW, ST, DC and DT were considered for tying with Cow-hitch or Nice-knots. The base of these Cow-hitch and Nice-knots was secured with surgeons` knots using 1–3 alternating throws. Tensile tests were conducted under physiologic conditions to evaluate knot slippage, ultimate force at rupture, and minimum number of throws ensuring 100% knot security.

Results
For both Cow-hitch and Nice-knots, 100% security was achieved with 2 securing throws for DC, DT, ST, and with 3 securing throws for FW. With these minimum numbers of securing throws, ultimate force was significantly higher for Nice-knots versus Cow-hitch tied with DT (p = 0.001) and slippage was significantly less with Nice-knots versus Cow-hitch tied with DC (p = 0.019).

Conclusions
The minimum number of securing throws required to achieve 100% security was 2 with DC, DT and ST for both Cow-hitch and Nice-knots configurations, in contrast to FW where 3 securing throws were needed. With these minimum numbers of securing throws, Nice-knots were associated with significantly higher ultimate forces when using DT and lower slippage with DC versus Cow-hitch knots.
Original languageEnglish
Pages (from-to)2867-2876
JournalEuropean Journal of Trauma and Emergency Surgery
Volume50
Early online date22 Jun 2024
DOIs
Publication statusPublished - 31 Dec 2024

Data Availability Statement

All data relevant to the study are included in the article.

Acknowledgements

This investigation was performed with the assistance of the AO Foundation.

Funding

The authors are not compensated and there are no other institutional subsidies, corporate affiliations, or funding sources supporting this work. This study was performed with the assistance of the AO Foundation.

Fingerprint

Dive into the research topics of 'Biomechanical evaluation of double-stranded knot configurations in high-strength sutures and tapes'. Together they form a unique fingerprint.

Cite this