Arterial pressure: Agreement between a brachial cuff-based device and radial tonometry

Chloe M. Park, Olga Korolkova, Justin E. Davies, Kim H. Parker, Jennifer H. Siggers, Katherine March, Therese Tillin, Nish Chaturvedi, Alun D. Hughes

Research output: Contribution to journalArticlepeer-review

28 Citations (SciVal)

Abstract

OBJECTIVES:: Aortic (central) blood pressure (BP) differs from brachial BP and may be a superior predictor of cardiovascular events. However, its measurement is currently restricted to research settings, owing to a moderate level of operator dependency. We tested a new noninvasive device in a large UK cohort. The device estimates central BP using measurements obtained with an upper arm cuff inflated to suprasystolic pressure. We compared these estimates with those obtained using radial tonometry as well as with invasively acquired measurements of aortic BP in a limited number of individuals. METHODS:: Consecutive cuff-based and tonometry-based estimates of the pressure waveform and the central BP were obtained from 1107 individuals (70±6 years). Short-term and long-term reproducibility studies were performed on 28 individuals. Simultaneous cuff-based and invasively measured pressure traces were acquired and compared in an additional six individuals (65±20 years). RESULTS:: Central systolic BP, as estimated by the cuff-based device, was found to be highly reproducible (coefficient of variation 4 and 8% for short and long-term reproducibility, respectively) and was comparable to that estimated by tonometry (average difference 3±6 mmHg, intraclass correlation coefficient=0.91). The cuff-based pressure waveforms were similar to those acquired invasively (cross-correlation coefficient 0.93), and the difference in the estimated central systolic BP was -5±8 mmHg (P=0.2). CONCLUSION:: Cuff-based devices show promise to simplify the measurement of central BP, whilst maintaining a similar fidelity to tonometry. This could lead to improved adoption of estimates of central BP in clinical practice.

Original languageEnglish
Pages (from-to)865-872
Number of pages8
JournalJournal of Hypertension
Volume32
Issue number4
DOIs
Publication statusPublished - 30 Apr 2014

Keywords

  • Brachial cuff
  • Central blood pressure
  • Invasive
  • Noninvasive
  • Tonometry

ASJC Scopus subject areas

  • Internal Medicine
  • Physiology
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Arterial pressure: Agreement between a brachial cuff-based device and radial tonometry'. Together they form a unique fingerprint.