An Alternative Approach to Adaptive Single-Pole Auto Reclosing in High-Voltage Transmission Systems Based on Variable Dead Time Control

Research output: Contribution to journalArticle

103 Citations (Scopus)

Abstract

This paper presents a new concept, based on variable dead time control, in adaptive single-pole auto reclosing (SPAR). The proposed scheme can give rise to a high rate of successful reclosing by adapting to variable dead times. The significance of this algorithm is that it uses the waveform patterns of the voltage transients following initial breaker opening. The performance of this proposed method is tested under a variety of fault locations on the Korean 765 kV system, and the outcome of the study clearly indicates that variable dead time auto-reclosing scheme can be used as an attractive and effective means of better management and operation of a high-voltage transmission system.
LanguageEnglish
Pages70-70
Number of pages1
JournalPower Engineering Review, IEEE
Volume21
Issue number4
StatusPublished - 2001

Fingerprint

Poles
Electric fault location
Electric potential

Keywords

  • high-voltage transmission lines
  • Adaptive single-pole auto reclosing
  • dead time control

Cite this

@article{dcb4e5eaa6554cfb8e99c7fe5f16a9e4,
title = "An Alternative Approach to Adaptive Single-Pole Auto Reclosing in High-Voltage Transmission Systems Based on Variable Dead Time Control",
abstract = "This paper presents a new concept, based on variable dead time control, in adaptive single-pole auto reclosing (SPAR). The proposed scheme can give rise to a high rate of successful reclosing by adapting to variable dead times. The significance of this algorithm is that it uses the waveform patterns of the voltage transients following initial breaker opening. The performance of this proposed method is tested under a variety of fault locations on the Korean 765 kV system, and the outcome of the study clearly indicates that variable dead time auto-reclosing scheme can be used as an attractive and effective means of better management and operation of a high-voltage transmission system.",
keywords = "high-voltage transmission lines, Adaptive single-pole auto reclosing, dead time control",
author = "Ahn, {S P} and Aggarwal, {R K} and Johns, {A T}",
year = "2001",
language = "English",
volume = "21",
pages = "70--70",
journal = "Power Engineering Review, IEEE",
issn = "0272-1724",
publisher = "IEEE",
number = "4",

}

TY - JOUR

T1 - An Alternative Approach to Adaptive Single-Pole Auto Reclosing in High-Voltage Transmission Systems Based on Variable Dead Time Control

AU - Ahn, S P

AU - Aggarwal, R K

AU - Johns, A T

PY - 2001

Y1 - 2001

N2 - This paper presents a new concept, based on variable dead time control, in adaptive single-pole auto reclosing (SPAR). The proposed scheme can give rise to a high rate of successful reclosing by adapting to variable dead times. The significance of this algorithm is that it uses the waveform patterns of the voltage transients following initial breaker opening. The performance of this proposed method is tested under a variety of fault locations on the Korean 765 kV system, and the outcome of the study clearly indicates that variable dead time auto-reclosing scheme can be used as an attractive and effective means of better management and operation of a high-voltage transmission system.

AB - This paper presents a new concept, based on variable dead time control, in adaptive single-pole auto reclosing (SPAR). The proposed scheme can give rise to a high rate of successful reclosing by adapting to variable dead times. The significance of this algorithm is that it uses the waveform patterns of the voltage transients following initial breaker opening. The performance of this proposed method is tested under a variety of fault locations on the Korean 765 kV system, and the outcome of the study clearly indicates that variable dead time auto-reclosing scheme can be used as an attractive and effective means of better management and operation of a high-voltage transmission system.

KW - high-voltage transmission lines

KW - Adaptive single-pole auto reclosing

KW - dead time control

M3 - Article

VL - 21

SP - 70

EP - 70

JO - Power Engineering Review, IEEE

T2 - Power Engineering Review, IEEE

JF - Power Engineering Review, IEEE

SN - 0272-1724

IS - 4

ER -