When using locked plating for bone fracture fixation, screw loosening is reported as one of the most frequent complications and is commonly attributed to an incorrect choice of screw configuration. Choosing a patient-optimized screw configuration is not straightforward as there are many interdependent variables that affect device performance. The aim of the study was to evaluate the influence that locking screw configuration has on loosening risk and how this is influenced by bone quality. This study uses finite element models that incorporate cortical bone heterogeneity, orthotropy, and geometrical nonlinearity to examine the effect of screw configuration on variables associated with loosening and interfragmentary motion. Strain levels within the bone were used as indicators of regions that may undergo loosening. The study found that, in healthy bone under axial loading, the most important variables influencing strain levels within the bone were the size of the bridging span (working length) and the plate rigidity. Unlike healthy bone, osteoporotic bone was found to be particularly sensitive to the spacing of the screws within the plate. Using two empty screw holes between the screws closest to the fracture was found to reduce the strain levels at the first screw by 49% in osteoporotic bone (compared to only 2.4% in healthy bone). The study also found that under torsional loading the total number of screws used was the most important variable with a 59% reduction in the strain around the screws closest to the fracture when using six rather than four screws in osteoporotic bone.
Original languageEnglish
Pages (from-to)1856-1864
JournalJournal of Orthopaedic Research
Volume34
Issue number11
Early online date14 Oct 2016
DOIs
Publication statusPublished - 30 Nov 2016

Fingerprint

Bone and Bones
Fracture Fixation
Bone Fractures
Weight-Bearing
Equipment and Supplies

Cite this

Age-related optimization of screw placement for reduced loosening risk in locked plating. / MacLeod, Alisdair R.; Simpson, A.Hamish R. W.; Pankaj, Pankaj.

In: Journal of Orthopaedic Research, Vol. 34, No. 11, 30.11.2016, p. 1856-1864.

Research output: Contribution to journalArticle

MacLeod, Alisdair R. ; Simpson, A.Hamish R. W. ; Pankaj, Pankaj. / Age-related optimization of screw placement for reduced loosening risk in locked plating. In: Journal of Orthopaedic Research. 2016 ; Vol. 34, No. 11. pp. 1856-1864.
@article{45493c0e15664bd19056ee47a8d440cb,
title = "Age-related optimization of screw placement for reduced loosening risk in locked plating",
abstract = "When using locked plating for bone fracture fixation, screw loosening is reported as one of the most frequent complications and is commonly attributed to an incorrect choice of screw configuration. Choosing a patient-optimized screw configuration is not straightforward as there are many interdependent variables that affect device performance. The aim of the study was to evaluate the influence that locking screw configuration has on loosening risk and how this is influenced by bone quality. This study uses finite element models that incorporate cortical bone heterogeneity, orthotropy, and geometrical nonlinearity to examine the effect of screw configuration on variables associated with loosening and interfragmentary motion. Strain levels within the bone were used as indicators of regions that may undergo loosening. The study found that, in healthy bone under axial loading, the most important variables influencing strain levels within the bone were the size of the bridging span (working length) and the plate rigidity. Unlike healthy bone, osteoporotic bone was found to be particularly sensitive to the spacing of the screws within the plate. Using two empty screw holes between the screws closest to the fracture was found to reduce the strain levels at the first screw by 49{\%} in osteoporotic bone (compared to only 2.4{\%} in healthy bone). The study also found that under torsional loading the total number of screws used was the most important variable with a 59{\%} reduction in the strain around the screws closest to the fracture when using six rather than four screws in osteoporotic bone.",
author = "MacLeod, {Alisdair R.} and Simpson, {A.Hamish R. W.} and Pankaj Pankaj",
year = "2016",
month = "11",
day = "30",
doi = "10.1002/jor.23193",
language = "English",
volume = "34",
pages = "1856--1864",
journal = "Journal of Orthopaedic Research",
issn = "0736-0266",
publisher = "John Wiley and Sons Inc.",
number = "11",

}

TY - JOUR

T1 - Age-related optimization of screw placement for reduced loosening risk in locked plating

AU - MacLeod, Alisdair R.

AU - Simpson, A.Hamish R. W.

AU - Pankaj, Pankaj

PY - 2016/11/30

Y1 - 2016/11/30

N2 - When using locked plating for bone fracture fixation, screw loosening is reported as one of the most frequent complications and is commonly attributed to an incorrect choice of screw configuration. Choosing a patient-optimized screw configuration is not straightforward as there are many interdependent variables that affect device performance. The aim of the study was to evaluate the influence that locking screw configuration has on loosening risk and how this is influenced by bone quality. This study uses finite element models that incorporate cortical bone heterogeneity, orthotropy, and geometrical nonlinearity to examine the effect of screw configuration on variables associated with loosening and interfragmentary motion. Strain levels within the bone were used as indicators of regions that may undergo loosening. The study found that, in healthy bone under axial loading, the most important variables influencing strain levels within the bone were the size of the bridging span (working length) and the plate rigidity. Unlike healthy bone, osteoporotic bone was found to be particularly sensitive to the spacing of the screws within the plate. Using two empty screw holes between the screws closest to the fracture was found to reduce the strain levels at the first screw by 49% in osteoporotic bone (compared to only 2.4% in healthy bone). The study also found that under torsional loading the total number of screws used was the most important variable with a 59% reduction in the strain around the screws closest to the fracture when using six rather than four screws in osteoporotic bone.

AB - When using locked plating for bone fracture fixation, screw loosening is reported as one of the most frequent complications and is commonly attributed to an incorrect choice of screw configuration. Choosing a patient-optimized screw configuration is not straightforward as there are many interdependent variables that affect device performance. The aim of the study was to evaluate the influence that locking screw configuration has on loosening risk and how this is influenced by bone quality. This study uses finite element models that incorporate cortical bone heterogeneity, orthotropy, and geometrical nonlinearity to examine the effect of screw configuration on variables associated with loosening and interfragmentary motion. Strain levels within the bone were used as indicators of regions that may undergo loosening. The study found that, in healthy bone under axial loading, the most important variables influencing strain levels within the bone were the size of the bridging span (working length) and the plate rigidity. Unlike healthy bone, osteoporotic bone was found to be particularly sensitive to the spacing of the screws within the plate. Using two empty screw holes between the screws closest to the fracture was found to reduce the strain levels at the first screw by 49% in osteoporotic bone (compared to only 2.4% in healthy bone). The study also found that under torsional loading the total number of screws used was the most important variable with a 59% reduction in the strain around the screws closest to the fracture when using six rather than four screws in osteoporotic bone.

U2 - 10.1002/jor.23193

DO - 10.1002/jor.23193

M3 - Article

VL - 34

SP - 1856

EP - 1864

JO - Journal of Orthopaedic Research

JF - Journal of Orthopaedic Research

SN - 0736-0266

IS - 11

ER -