A membrane ozonation contactor was built to investigate ozonation using tubular membranes and inform computational fluid dynamics (CFD) studies. Non-porous tubular polydimethylsiloxane (PDMS) membranes of 1.0–3.2 mm inner diameter were tested at ozone gas concentrations of 110–200 g/m3 and liquid side velocities of 0.002–0.226 m/s. The dissolved ozone concentration could be adjusted to up to 14 mg O3/L and increased with decreasing membrane diameter and liquid side velocity. Experimental mass transfer coefficients and molar fluxes of ozone were 2.4 × 10−6 m/s and 1.1 × 10−5 mol/(m2 s), respectively, for the smallest membrane. CFD modelling could predict the final ozone concentrations but slightly overestimated mass transfer coefficients and molar fluxes of ozone. Model contaminant degradation experiments and UV light absorption measurements of ozonated water samples in both ozone (O3) and peroxone (H2O2/O3) reaction systems in pure water, river water, wastewater effluent, and solutions containing humic acid show that the contactor system can be used to generate information on the reactivity of ozone with different water matrices. Combining simple membrane contactors with CFD allows for prediction of ozonation performance under a variety of conditions, leading to improved bubble-less ozone systems for water treatment.
Original languageEnglish
Article number1416
Number of pages14
JournalWater
Volume10
Issue number10
DOIs
Publication statusPublished - 10 Oct 2018

Cite this

A Single Tube Contactor for Testing Membrane Ozonation. / Zoumpouli, Garyfalia; Baker, Robert; Taylor, Caitlin; Chippendale, Matthew ; Smithers, Chloë; Ho, Sean; Mattia, Davide; Chew, Yong-Min; Wenk, Jannis.

In: Water, Vol. 10, No. 10, 1416, 10.10.2018.

Research output: Contribution to journalArticle

@article{482db3b6a9e44ed9ac9675d765599528,
title = "A Single Tube Contactor for Testing Membrane Ozonation",
abstract = "A membrane ozonation contactor was built to investigate ozonation using tubular membranes and inform computational fluid dynamics (CFD) studies. Non-porous tubular polydimethylsiloxane (PDMS) membranes of 1.0–3.2 mm inner diameter were tested at ozone gas concentrations of 110–200 g/m3 and liquid side velocities of 0.002–0.226 m/s. The dissolved ozone concentration could be adjusted to up to 14 mg O3/L and increased with decreasing membrane diameter and liquid side velocity. Experimental mass transfer coefficients and molar fluxes of ozone were 2.4 × 10−6 m/s and 1.1 × 10−5 mol/(m2 s), respectively, for the smallest membrane. CFD modelling could predict the final ozone concentrations but slightly overestimated mass transfer coefficients and molar fluxes of ozone. Model contaminant degradation experiments and UV light absorption measurements of ozonated water samples in both ozone (O3) and peroxone (H2O2/O3) reaction systems in pure water, river water, wastewater effluent, and solutions containing humic acid show that the contactor system can be used to generate information on the reactivity of ozone with different water matrices. Combining simple membrane contactors with CFD allows for prediction of ozonation performance under a variety of conditions, leading to improved bubble-less ozone systems for water treatment.",
author = "Garyfalia Zoumpouli and Robert Baker and Caitlin Taylor and Matthew Chippendale and Chlo{\"e} Smithers and Sean Ho and Davide Mattia and Yong-Min Chew and Jannis Wenk",
year = "2018",
month = "10",
day = "10",
doi = "10.3390/w10101416",
language = "English",
volume = "10",
journal = "Water",
issn = "2073-4441",
publisher = "MDPI",
number = "10",

}

TY - JOUR

T1 - A Single Tube Contactor for Testing Membrane Ozonation

AU - Zoumpouli, Garyfalia

AU - Baker, Robert

AU - Taylor, Caitlin

AU - Chippendale, Matthew

AU - Smithers, Chloë

AU - Ho, Sean

AU - Mattia, Davide

AU - Chew, Yong-Min

AU - Wenk, Jannis

PY - 2018/10/10

Y1 - 2018/10/10

N2 - A membrane ozonation contactor was built to investigate ozonation using tubular membranes and inform computational fluid dynamics (CFD) studies. Non-porous tubular polydimethylsiloxane (PDMS) membranes of 1.0–3.2 mm inner diameter were tested at ozone gas concentrations of 110–200 g/m3 and liquid side velocities of 0.002–0.226 m/s. The dissolved ozone concentration could be adjusted to up to 14 mg O3/L and increased with decreasing membrane diameter and liquid side velocity. Experimental mass transfer coefficients and molar fluxes of ozone were 2.4 × 10−6 m/s and 1.1 × 10−5 mol/(m2 s), respectively, for the smallest membrane. CFD modelling could predict the final ozone concentrations but slightly overestimated mass transfer coefficients and molar fluxes of ozone. Model contaminant degradation experiments and UV light absorption measurements of ozonated water samples in both ozone (O3) and peroxone (H2O2/O3) reaction systems in pure water, river water, wastewater effluent, and solutions containing humic acid show that the contactor system can be used to generate information on the reactivity of ozone with different water matrices. Combining simple membrane contactors with CFD allows for prediction of ozonation performance under a variety of conditions, leading to improved bubble-less ozone systems for water treatment.

AB - A membrane ozonation contactor was built to investigate ozonation using tubular membranes and inform computational fluid dynamics (CFD) studies. Non-porous tubular polydimethylsiloxane (PDMS) membranes of 1.0–3.2 mm inner diameter were tested at ozone gas concentrations of 110–200 g/m3 and liquid side velocities of 0.002–0.226 m/s. The dissolved ozone concentration could be adjusted to up to 14 mg O3/L and increased with decreasing membrane diameter and liquid side velocity. Experimental mass transfer coefficients and molar fluxes of ozone were 2.4 × 10−6 m/s and 1.1 × 10−5 mol/(m2 s), respectively, for the smallest membrane. CFD modelling could predict the final ozone concentrations but slightly overestimated mass transfer coefficients and molar fluxes of ozone. Model contaminant degradation experiments and UV light absorption measurements of ozonated water samples in both ozone (O3) and peroxone (H2O2/O3) reaction systems in pure water, river water, wastewater effluent, and solutions containing humic acid show that the contactor system can be used to generate information on the reactivity of ozone with different water matrices. Combining simple membrane contactors with CFD allows for prediction of ozonation performance under a variety of conditions, leading to improved bubble-less ozone systems for water treatment.

U2 - 10.3390/w10101416

DO - 10.3390/w10101416

M3 - Article

VL - 10

JO - Water

JF - Water

SN - 2073-4441

IS - 10

M1 - 1416

ER -