Abstract
A transient MATLAB/SIMULINK model of induction motor with stator winding turn faults is developed. The model has features of simulating variable load level, stator winding turn faults in each phase and different number of short turns. The transient response is examined in terms of current under variable load level. The harmonic frequency in simulated stator current indicates stator winding turn fault. The model is validated by comparing simulated and measured stator current with different number of short turns and load levels. The model can be further used in model-aid induction motor fault diagnosis system.
Original language | English |
---|---|
Pages | 1-5 |
Number of pages | 5 |
Publication status | Published - 29 Sept 2012 |
Event | 2012 22nd Australasian Universities Power Engineering Conference (AUPEC) - Bali, Indonesia Duration: 26 Sept 2012 → 29 Sept 2012 |
Conference
Conference | 2012 22nd Australasian Universities Power Engineering Conference (AUPEC) |
---|---|
Country/Territory | Indonesia |
City | Bali |
Period | 26/09/12 → 29/09/12 |