• 4 EAST 2.08B

Accepting PhD Students

1976 …2019
If you made any changes in Pure these will be visible here soon.

Research Output 1976 2019

Filter
Article
2018
61 Downloads (Pure)

The equivalence of multi-axis spine systems: Recommended stiffness limits using a standardized testing protocol

Holsgrove, T., Amin, D., Ramos Pascual, S., Ding, B., Welch, W., Gheduzzi, S., Miles, A., Winkelstein, B. & Costi, J., 21 Mar 2018, In : Journal of Biomechanics. 70, p. 59-66 8 p.

Research output: Contribution to journalArticle

Open Access
File
Spine
Stiffness
Testing
Loads (forces)
Polymers
2017
3 Citations (Scopus)
169 Downloads (Pure)
Open Access
File
Hip Prosthesis
Hip Replacement Arthroplasties
Head
Lasers
3 Citations (Scopus)
104 Downloads (Pure)
Open Access
File
Surface roughness
Materials Testing
Chromium
Cobalt
Titanium
3 Citations (Scopus)
71 Downloads (Pure)

Non-invasive vibrometry-based diagnostic detection of acetabular cup loosening in Total Hip Replacement (THR)

Alshuhri, A. A., Holsgrove, T. P., Miles, A. W. & Cunningham, J. L., Oct 2017, In : Medical Engineering & Physics . 48, p. 188-195

Research output: Contribution to journalArticle

Open Access
File
Hip Replacement Arthroplasties
Bone
Imaging techniques
Bone and Bones
Composite materials
1 Citation (Scopus)
119 Downloads (Pure)

The application of physiological loading using a dynamic, multi-axis spine simulator

Holsgrove, T., Miles, A. & Gheduzzi, S., Mar 2017, In : Medical Engineering & Physics . 41, p. 74-80 7 p.

Research output: Contribution to journalArticle

Open Access
File
Axial loads
Noise
Spine
Simulators
Testing
2016
3 Citations (Scopus)
137 Downloads (Pure)

A biomechanical study of the effects of simulated ulnar deviation on silicone finger joint implant failure

Drayton, P., Morgan, B. W., Davies, M. C., Giddins, G. E. B. & Miles, A. W., Nov 2016, In : Journal of Hand Surgery-European Volume. 41, 9, p. 944-947 4 p.

Research output: Contribution to journalArticle

File
8 Citations (Scopus)
110 Downloads (Pure)

The effect of dynamic hip motion on the micromotion of press-fit acetabular cups in six degrees of freedom

Crosnier, E., Keogh, P. & Miles, A., 1 Aug 2016, In : Medical Engineering & Physics . 38, 8, p. 717-724 8 p.

Research output: Contribution to journalArticle

Open Access
File
Hip
Hip Joint
Bone
Simulators
Osseointegration
1 Citation (Scopus)
106 Downloads (Pure)
Open Access
File
Knee prostheses
Bone
Strain measurement
Composite materials
Surgery
2015
3 Citations (Scopus)
116 Downloads (Pure)

An investigation into axial impacts of the cervical spine using digital image correlation

Holsgrove, T. P., Cazzola, D., Preatoni, E., Trewartha, G., Miles, A. W., Gill, H. S. & Gheduzzi, S., 1 Aug 2015, In : The Spine Journal. 15, 8, p. 1856-1863 8 p.

Research output: Contribution to journalArticle

Open Access
File
Spine
Wounds and Injuries
Football
Swine
Lordosis
1 Citation (Scopus)
110 Downloads (Pure)

Cement brand and preparation effects cement-in-cement mantle shear strength

Holsgrove, T. P., Pentlow, A., Spencer, R. F. & Miles, A. W., Jan 2015, In : Hip International. 25, 1, p. 67-71

Research output: Contribution to journalArticle

Open Access
File
Shear Strength
Methylmethacrylate
Tobramycin
Bone Cements
Arthroplasty
10 Citations (Scopus)
128 Downloads (Pure)

Development of a non-invasive diagnostic technique for acetabular component loosening in total hip replacements

Alshuhri, A., Holsgrove, T., Miles, A. W. & Cunningham, J., Aug 2015, In : Medical Engineering & Physics . 37, 8, p. 739-745 7 p.

Research output: Contribution to journalArticle

Open Access
File
Hip Replacement Arthroplasties
Vibration
Accelerometers
Ultrasonics
Tissue
1 Citation (Scopus)
117 Downloads (Pure)
File
Stiffness matrix
8 Citations (Scopus)
105 Downloads (Pure)

The dynamic, six-axis stiffness matrix testing of porcine spinal specimens

Holsgrove, T. P., Gill, H. S., Miles, A. W. & Gheduzzi, S., 1 Jan 2015, In : The Spine Journal. 15, 1, p. 176-184 9 p.

Research output: Contribution to journalArticle

Open Access
File
Spine
Swine
Conflict of Interest
Organized Financing
Biomechanical Phenomena
2014
16 Citations (Scopus)
135 Downloads (Pure)
Open Access
File
Bone
Geometry
Physiological models
Foams
Testing
3 Citations (Scopus)
106 Downloads (Pure)
File
Arthroplasty
Biomechanics
Simulators
Joints (anatomy)
Pressure sensors
18 Citations (Scopus)
100 Downloads (Pure)

Low torque levels can initiate a removal of the passivation layer and cause fretting in modular hip stems

Jauch, S. Y., Coles, L. G., Ng, L. V., Miles, A. W. & Gill, H. S., Sep 2014, In : Medical Engineering & Physics . 36, 9, p. 1140-1146

Research output: Contribution to journalArticle

Open Access
File
Torque
Passivation
Hip
Axial loads
Prostheses and Implants
19 Citations (Scopus)
94 Downloads (Pure)

Strong correlation between the morphology of the proximal femur and the geometry of the distal femoral trochlea

Wright, S. J., Boymans, T. A. E. J., Grimm, B., Miles, A. W. & Kessler, O., 1 Dec 2014, In : Knee Surgery, Sports Traumatology, Arthroscopy. 22, 12, p. 2900-2910 11 p.

Research output: Contribution to journalArticle

Open Access
File
Thigh
Biomechanical Phenomena
Femur
Knee Replacement Arthroplasties
Neck
10 Citations (Scopus)
108 Downloads (Pure)

The development of a dynamic, six-axis spine simulator

Holsgrove, T. P., Gheduzzi, S., Gill, H. S. & Miles, A. W., 1 Jul 2014, In : The Spine Journal. 14, 7, p. 1308-1317 9 p.

Research output: Contribution to journalArticle

Open Access
File
Spine
Swine
Biomechanical Phenomena
Research
2013
7 Citations (Scopus)
Knee prostheses
Prosthetics
Tendons
Hinges
Salvaging
2 Citations (Scopus)
103 Downloads (Pure)
Open Access
File
Arthrodesis
pins
Wrist
Canidae
dogs
5 Citations (Scopus)

Biomechanical study of the efficacy of a new design of wrist guard

Maurel, M. L., Fitzgerald, L. G., Miles, A. W. & Giddins, G. E. B., Jun 2013, In : Clinical Biomechanics. 25, 5, p. 509-513

Research output: Contribution to journalArticle

Wrist
Articular Range of Motion
Upper Extremity
Hand
Wounds and Injuries
111 Downloads (Pure)
Open Access
File
Torque
Arthroplasty
Debonding
Bone
Stiffness
15 Citations (Scopus)

Stabilisation of the syndesmosis in the maisonneuve fracture: A biomechanical study comparing 2-hole locking plate and quadricortical screw fixation

Gardner, R., Yousri, T., Holmes, F., Clark, D., Pollintine, P., Miles, A. W. & Jackson, M., Apr 2013, In : Journal of Orthopaedic Trauma. 27, 4, p. 212-216

Research output: Contribution to journalArticle

Extremities
Fibula
Bone Fractures
Torque
Cadaver
2012
9 Citations (Scopus)
132 Downloads (Pure)

Basic biomechanics and biomaterials

Miles, A. W. & Gheduzzi, S., 2012, In : Surgery (Oxford). 30, 2, p. 86-91 6 p.

Research output: Contribution to journalArticle

Open Access
File
Textbooks
Biocompatible Materials
Biomechanical Phenomena
Orthopedics
Reading
2011
3 Citations (Scopus)

Optimal configuration of the spiral linking technique for tendon repair. Biomechanical evaluation

Kulikov, Y. I., Vinogradova, Y., Miles, A. W. & Giddins, G., Mar 2011, In : Journal of Hand Surgery-European Volume. 36E, 3, p. 210-214 5 p.

Research output: Contribution to journalArticle

Tendons
Sutures
2010
6 Citations (Scopus)

Sensing methodology for in vivo stability evaluation of total hip and knee arthroplasty

Hao, S. Y., Taylor, J. T., Bowen, C. R., Gheduzzi, S. & Miles, A. W., Jan 2010, In : Sensors and Actuators A-Physical. 157, 1, p. 150-160 11 p.

Research output: Contribution to journalArticle

Arthroplasty
Calibration
methodology
evaluation
reluctance
16 Citations (Scopus)

The effect of 4 mm bicortical drill hole defect on bone strength in a pig femur model

Ho, K. W. K., Gilbody, J., Jameson, T. & Miles, A. W., 2010, In : Archives of Orthopaedic and Trauma Surgery. 130, 6, p. 797-802 6 p.

Research output: Contribution to journalArticle

Femur
Swine
Bone and Bones
Torque
Calcium Sulfate
2009
5 Citations (Scopus)

A computer model of the artificially ventilated human respiratory system in adult intensive care

Wilson, A. J., Murphy, C. M., Brook, B. S., Breen, D., Miles, A. W. & Tilley, D. G., Nov 2009, In : Medical Engineering & Physics. 31, 9, p. 1118-1133 16 p.

Research output: Contribution to journalArticle

Respiratory system
Critical Care
Respiratory System
Computer Simulation
Mechanical Ventilators
3 Citations (Scopus)
106 Downloads (Pure)

Basic biomechanics and biomaterials

Miles, A. W. & Gheduzzi, S., 1 Feb 2009, In : Surgery (Oxford). 27, 2, p. 90-95 6 p.

Research output: Contribution to journalArticle

Open Access
File
Textbooks
Biocompatible Materials
Biomechanical Phenomena
Orthopedics
Reading
43 Citations (Scopus)

Influence of setting liquid composition and liquid-to-powder ratio on properties of a Mg-substituted calcium phosphate cement

Pina, S., Olhero, S. M., Gheduzzi, S., Miles, A. W. & Ferreira, J. M. F., May 2009, In : Acta Biomaterialia. 5, 4, p. 1233-1240 8 p.

Research output: Contribution to journalArticle

Calcium phosphate
Powders
Cements
Liquids
Chemical analysis
18 Citations (Scopus)
Bioceramics
Calcium phosphate
Immersion
Mechanical properties
Water
18 Citations (Scopus)

Numerical and experimental simulation of the effect of long bone fracture healing stages on ultrasound transmission across an idealized fracture

Gheduzzi, S., Dodd, S. P., Miles, A. W., Humphrey, V. F. & Cunningham, J. L., Aug 2009, In : Journal of the Acoustical Society of America. 126, 2, p. 887-894 8 p.

Research output: Contribution to journalArticle

healing
bones
transmission loss
simulation
Simulation
2 Citations (Scopus)

Theoretical models for the quantification of lung injury using ventilation and perfusion distributions

Brook, B. S., Murphy, C. M., Breen, D., Miles, A. W., Tilley, D. G. & Wilson, A. J., Jun 2009, In : Computational and Mathematical Methods in Medicine. 10, 2, p. 139-154 16 p.

Research output: Contribution to journalArticle

Pulmonary diseases
Normal Distribution
Lung Injury
Ventilation
Normal distribution
2008
5 Citations (Scopus)

Intradiscal pressure changes with dynamic pedicle screw systems

Dath, R., Sirkett, D. M., Gheduzzi, S. & Miles, A. W., 2008, In : Journal of Spinal Disorders and Techniques. 21, 4, p. 241-246 6 p.

Research output: Contribution to journalArticle

Pressure
Spine
Pedicle Screws
Swine
Pathology
16 Citations (Scopus)

Locking plates increase the strength of dynamic hip screws

Jewell, D. P. A., Gheduzzi, S., Mitchell, M. S. & Miles, A. W., 2008, In : Injury. 39, 2, p. 209-212 4 p.

Research output: Contribution to journalArticle

Hip
Femur
Hip Fractures
Thigh
Materials Testing

Numerical modelling and in-vitro studies of ultrasound signal loss across fractures in cortical bone mimics

Humphrey, V. F., Dodd, S. P., Gheduzzi, S., Cunningham, J. L. & Miles, A. W., 2008, In : Journal of the Acoustical Society of America. 123, 5, p. 3514-3514 1 p.

Research output: Contribution to journalArticle

bones
propagation
healing
transit time
ultrasonic radiation
8 Citations (Scopus)

Techniques for manufacturing FGM bioceramics

Hsu, Y. H., Turner, I. G. & Miles, A. W., 2008, In : Key Engineering Materials. 361-363, p. 123-126 4 p.

Research output: Contribution to journalArticle

2 Citations (Scopus)

The effect of slip loading on the properties of porous calcium phosphate bioceramics

Hsu, Y. H., Turner, I. G. & Miles, A. W., 2008, In : Key Engineering Materials. 361-363, p. 19-22 4 p.

Research output: Contribution to journalArticle

Bioceramics
Calcium phosphate
Bending strength
Powders
Compressive strength
32 Citations (Scopus)

Ultrasound transmission loss across transverse and oblique bone fractures: an in-vitro study

Dodd, S. P., Cunningham, J. L., Miles, A. W., Gheduzzi, S. & Humphrey, V. F., Mar 2008, In : Ultrasound in Medicine & Biology. 34, 3, p. 454-462 9 p.

Research output: Contribution to journalArticle

Bone Fractures
transmission loss
bones
arrivals
time lag
2007
67 Citations (Scopus)

A brief history of total ankle replacement and a review of the current status

Vickerstaff, J. A., Miles, A. W. & Cunningham, J. L., 2007, In : Medical Engineering & Physics. 29, 10, p. 1056-1064 9 p.

Research output: Contribution to journalArticle

Ankle Replacement Arthroplasty
Prosthetics
Arthrodesis
Ankle
Prostheses and Implants
51 Citations (Scopus)

Anatomical measurements of porcine lumbar vertebrae

Dath, R., Porter, K. M. & Miles, A. W., 2007, In : Clinical Biomechanics. 22, 5, p. 607-613 7 p.

Research output: Contribution to journalArticle

24 Citations (Scopus)

An in vitro biomechanical study comparing the spiral linking technique against the pulvertaft weave for tendon repair

Kulikov, Y. I., Dodd, S., Gheduzzi, S., Miles, A. W. & Giddins, G. E., 2007, In : Journal of Hand Surgery: European Volume. 32, 7, p. 377-381 5 p.

Research output: Contribution to journalArticle

Tendons
Repair
Stiffness
Testing
30 Citations (Scopus)

An in vitro study of ultrasound signal loss across simple fractures in cortical bone mimics and bovine cortical bone samples

Dodd, S. P., Cunningham, J. L., Miles, A. W., Gheduzzi, S. & Humphrey, V. F., 2007, In : Bone. 40, 3, p. 656-661 6 p.

Research output: Contribution to journalArticle

Fracture Healing
In Vitro Techniques
Cortical Bone
Ultrasonic Waves
53 Citations (Scopus)
7 Citations (Scopus)

In-vitro pressurization of the acetabular cement mantle - the effect of a flange

Lankaster, B. J. A., Sabri, O., Gheduzzi, S., Stoney, J. D., Miles, A. W. & Bannister, G. C., 2007, In : Journal of Arthroplasty. 22, 5, p. 738-744 7 p.

Research output: Contribution to journalArticle

1 Citation (Scopus)
Bone
Grafts
Subsidence
Canals
Surgery
29 Citations (Scopus)

Mechanical characterization of dense calcium phosphate bioceramics with interconnected porosity

Hsu, Y. H., Turner, I. G. & Miles, A. W., 2007, In : Journal of Materials Science: Materials Medicine. 18, 11, p. 2319-2329 11 p.

Research output: Contribution to journalArticle

23 Citations (Scopus)
Bone
Ultrasonics
Geometry
Mechanical properties
Ultrasonic waves
3 Citations (Scopus)

Quantification of lung injury using ventilation and perfusion distributions obtained from gamma scintigraphy

Brook, B. S., Murphy, C. M., Breen, D., Miles, A. W., Tilley, D. G. & Wilson, A. J., 2007, In : Physiological Measurement. 28, 12, p. 1451-1464 14 p.

Research output: Contribution to journalArticle