If you made any changes in Pure these will be visible here soon.

Research Output

Filter
Article
2018

First Demonstration of Velocity Selective Recording from the Pig Vagus using a Nerve Cuff shows Respiration Afferents

Metcalfe, B., Nielsen, T., Donaldson, N., Hunter, A. J. & Taylor, J., 1 Feb 2018, In : Biomedical Engineering Letters. 8, 1, p. 127-136 10 p.

Research output: Contribution to journalArticle

Open Access
File
7 Citations (Scopus)
44 Downloads (Pure)

Freeze cast porous barium titanate for enhanced piezoelectric energy harvesting

Roscow, J. I., Zhang, Y., Kraśny, M. J., Lewis, R. W. C., Taylor, J. & Bowen, C. R., 8 May 2018, In : Journal of Physics D: Applied Physics. 51, 22, p. 1-18 18 p., 225301.

Research output: Contribution to journalArticle

Open Access
File
10 Citations (Scopus)
24 Downloads (Pure)
2017

A New Method for Neural Spike Alignment: The Centroid Filter

Metcalfe, B., Clarke, C., Donaldson, N. & Taylor, J., 30 Nov 2017, In : IEEE Transactions on Neural Systems and Rehabilitation Engineering. 25, 11, p. 1988-1997 10 p.

Research output: Contribution to journalArticle

Open Access
File
161 Downloads (Pure)

An Implantable ENG Detector with In-System Velocity Selective Recording (VSR) Capability

Clarke, C., Rieger, R., Schuettler, M., Donaldson, N. & Taylor, J., 1 Jun 2017, In : Medical and Biological Engineering and Computing. 55, 6, p. 885-895

Research output: Contribution to journalArticle

Open Access
File
122 Downloads (Pure)
Open Access
File
29 Citations (Scopus)
105 Downloads (Pure)
Open Access
File
2 Citations (Scopus)
30 Downloads (Pure)
2016
Open Access
File
12 Citations (Scopus)
99 Downloads (Pure)
Open Access
File
6 Citations (Scopus)
35 Downloads (Pure)

Hybrid synthetic receptors on MOSFET devices for detection of prostate specific antigen in human plasma

Tamboli, V. K., Bhalla, N., Jolly, P., Bowen, C. R., Taylor, J. T., Bowen, J. L., Allender, C. J. & Estrela, P., 6 Dec 2016, In : Analytical Chemistry. 88, 23, p. 11486-11490 5 p.

Research output: Contribution to journalArticle

Open Access
File
15 Citations (Scopus)
139 Downloads (Pure)

Inexpensive and fast pathogenic bacteria screening using field-effect transistors

Formisano, N., Bhalla, N., Heeran, M., Reyes Martinez, J., Sarkar, A., Laabei, M., Jolly, P., Bowen, C. R., Taylor, J. T., Flitsch, S. & Estrela, P., 15 Nov 2016, In : Biosensors and Bioelectronics. 85, p. 103-109 7 p.

Research output: Contribution to journalArticle

Open Access
File
9 Citations (Scopus)
126 Downloads (Pure)
Open Access
File
17 Citations (Scopus)
75 Downloads (Pure)

Understanding the peculiarities of the piezoelectric effect in macro-porous BaTiO3

Roscow, J., Topolov, V. Y., Bowen, C., Taylor, J. & Panich, A. E., 2016, In : Science and Technology of Advanced Materials. 17, 1, p. 769-776

Research output: Contribution to journalArticle

Open Access
File
5 Citations (Scopus)
85 Downloads (Pure)
2015

A modified figure of merit for pyroelectric energy harvesting

Bowen, C., Taylor, J., Le Boulbar, E., Zabek, D. A. & Topolov, V. Y., 1 Jan 2015, In : Materials Letters. 138, p. 243-246 4 p.

Research output: Contribution to journalArticle

Open Access
File
41 Citations (Scopus)
174 Downloads (Pure)

A new method for spike extraction using velocity selective recording demonstrated with physiological ENG in Rat

Metcalfe, B. W., Chew, D. J., Clarke, C. T., Donaldson, N. D. N. & Taylor, J. T., 15 Aug 2015, In : Journal of Neuroscience Methods. 251, p. 47-55 9 p.

Research output: Contribution to journalArticle

Open Access
File
8 Citations (Scopus)
113 Downloads (Pure)
Open Access
File
57 Citations (Scopus)
184 Downloads (Pure)

Porous ferroelectrics for energy harvesting applications

Roscow, J., Zhang, Y., Taylor, J. & Bowen, C. R., Nov 2015, In : European Physical Journal - Special Topics. 224, 14-15, p. 2949-2966 18 p.

Research output: Contribution to journalArticle

File
25 Citations (Scopus)
141 Downloads (Pure)
2014

Manufacturing and characterization of Magnéli phase conductive fibres

Adamaki, V., Clemens, F., Ragulis, P., Pennock, S. R., Taylor, J. & Bowen, C. R., 14 Jun 2014, In : Journal of Materials Chemistry A. 2, 22, p. 8328-8333 6 p.

Research output: Contribution to journalArticle

Open Access
File
22 Citations (Scopus)
123 Downloads (Pure)

Pyroelectric materials and devices for energy harvesting applications

Bowen, C. R., Taylor, J., Leboulbar, E., Zabek, D., Chauhan, A. & Vaish, R., 1 Dec 2014, In : Energy & Environmental Science. 7, 12, p. 3836-3856 21 p.

Research output: Contribution to journalArticle

File
274 Citations (Scopus)
200 Downloads (Pure)

Re-oxidation mechanism and kinetics of fine scale Ti-Magnéli phases in fibre form using thermo-gravimetric analysis

Adamaki, V., Clemens, F., Taylor, J., Mays, T. J. & Bowen, C. R., Nov 2014, In : Journal of Materials Science. 49, 21, p. 7597-7603 7 p.

Research output: Contribution to journalArticle

Open Access
File
3 Citations (Scopus)
57 Downloads (Pure)
2013

A switched-capacitor front-end for velocity-selective ENG recording

Rieger, R. & Taylor, J., 2013, In : IEEE Transactions on Biomedical Circuits and Systems. 7, 4, p. 480-488 9 p.

Research output: Contribution to journalArticle

Open Access
File
6 Citations (Scopus)
119 Downloads (Pure)

Fibre-selective recording from the peripheral nerves of frogs using a multi-electrode cuff

Schuettler, M., Donaldson, N., Seetohul, V. & Taylor, J., 1 Jun 2013, In : Journal of Neural Engineering. 10, 3, 036016.

Research output: Contribution to journalArticle

27 Citations (Scopus)

Improved signal processing methods for velocity selective neural recording using multi-electrode cuffs

Al-Shueli, A., Clarke, C. T., Donaldson, N. & Taylor, J. T., 2013, In : IEEE Transactions on Biomedical Circuits and Systems. 8, 3, p. 401-410 11 p.

Research output: Contribution to journalArticle

Open Access
File
6 Citations (Scopus)
136 Downloads (Pure)
2012

AC electrical properties of TiO2 and Magnéli phases, TinO2n−1

Regonini, D., Adamaki, V., Bowen, C. R., Dent, A. C. E., Pennock, S. R. & Taylor, J., 14 Dec 2012, In : Solid State Ionics. 229, p. 38-44 7 p.

Research output: Contribution to journalArticle

33 Citations (Scopus)

Modification of standard CMOS technology for cell-based biosensors

Graham, A. H. D., Surguy, S. M., Langlois, P., Bowen, C. R., Taylor, J. & Robbins, J., 15 Jan 2012, In : Biosensors and Bioelectronics. 31, 1, p. 458-462 5 p.

Research output: Contribution to journalArticle

Open Access
File
8 Citations (Scopus)
126 Downloads (Pure)

The theory of velocity selective neural recording: a study based on simulation

Taylor, J., Schuettler, M., Clarke, C. T. & Donaldson, N., 1 Mar 2012, In : Medical and Biological Engineering and Computing. 50, 3, p. 309-318 10 p.

Research output: Contribution to journalArticle

Open Access
File
12 Citations (Scopus)
121 Downloads (Pure)
2011

A low-noise front-end for multiplexed ENG recording using CMOS technology

Taylor, J. & Rieger, R., Aug 2011, In : Analog Integrated Circuits and Signal Processing. 68, 2, p. 163-174 12 p.

Research output: Contribution to journalArticle

6 Citations (Scopus)

Commercialisation of CMOS integrated circuit technology in multi-electrode arrays for neuroscience and cell-based biosensors

Graham, A. H. D., Robbins, J., Bowen, C. R. & Taylor, J., May 2011, In : Sensors. 11, 5, p. 4943-4971 29 p.

Research output: Contribution to journalArticle

31 Citations (Scopus)

Impedance spectroscopy analysis of TinO2n-1 Magnéli phases

Regonini, D., Dent, A. C. E., Bowen, C. R., Pennock, S. R. & Taylor, J., Dec 2011, In : Materials Letters. 65, 23-24, p. 3590-3592 3 p.

Research output: Contribution to journalArticle

Open Access
File
24 Citations (Scopus)
136 Downloads (Pure)

New prototype assembly methods for biosensor integrated circuits

Graham, A. H. D., Bowen, C. R., Surguy, S. M., Robbins, J. & Taylor, J., Oct 2011, In : Medical Engineering & Physics. 33, 8, p. 973-979 7 p.

Research output: Contribution to journalArticle

9 Citations (Scopus)
2010

Nanostructured electrodes for biocompatible CMOS integrated circuits

Graham, A. H. D., Bowen, C. R., Robbins, J., Lalev, G., Marken, F. & Taylor, J., 3 Jun 2010, In : Sensors and Actuators B-Chemical. 147, 2, p. 697-706 10 p.

Research output: Contribution to journalArticle

11 Citations (Scopus)

Sensing methodology for in vivo stability evaluation of total hip and knee arthroplasty

Hao, S. Y., Taylor, J. T., Bowen, C. R., Gheduzzi, S. & Miles, A. W., Jan 2010, In : Sensors and Actuators A-Physical. 157, 1, p. 150-160 11 p.

Research output: Contribution to journalArticle

6 Citations (Scopus)
2009

An Adaptive Sampling System for Sensor Nodes in Body Area Networks

Rieger, R. & Taylor, J. T., 2009, In : IEEE Transactions on Neural Systems and Rehabilitation Engineering. 17, 2, p. 183-189 7 p.

Research output: Contribution to journalArticle

File
26 Citations (Scopus)
124 Downloads (Pure)

An implanted system for multi-site nerve cuff-based ENG recording using velocity selectivity

Clarke, C. T., Xu, X., Rieger, R., Taylor, J. & Donaldson, N., 1 Feb 2009, In : Analog Integrated Circuits and Signal Processing. 58, 2, p. 91-104 14 p.

Research output: Contribution to journalArticle

11 Citations (Scopus)

Design strategies for multi-channel low-noise recording systems

Rieger, R. & Taylor, J. T., Feb 2009, In : Analog Integrated Circuits and Signal Processing. 58, 2, p. 123-133 11 p.

Research output: Contribution to journalArticle

21 Citations (Scopus)

Formation of a porous alumina electrode as a low-cost CMOS neuronal interface

Graham, A. H. D., Bowen, C. R., Robbins, J. & Taylor, J., 28 Apr 2009, In : Sensors and Actuators B-Chemical. 138, 1, p. 296-303 8 p.

Research output: Contribution to journalArticle

32 Citations (Scopus)

Neuronal cell biocompatibility and adhesion to modified CMOS electrodes

Graham, A. H. D., Bowen, C. R., Taylor, J. & Robbins, J., 1 Oct 2009, In : Biomedical Microdevices. 11, 5, p. 1091-1101 11 p.

Research output: Contribution to journalArticle

23 Citations (Scopus)
2008

Noise and selectivity of velocity-selective multi-electrode nerve cuffs

Donaldson, N., Rieger, R., Schuettler, M. & Taylor, J., 1 Oct 2008, In : Medical and Biological Engineering and Computing. 46, 10, p. 1005-1018 14 p.

Research output: Contribution to journalArticle

29 Citations (Scopus)
2006

Very low-noise ENG amplifier system using CMOS technology

Rieger, R., Schuettler, M., Pal, D., Clarke, C., Langlois, P., Taylor, J. & Donaldson, N., 2006, In : IEEE Transactions on Neural Systems and Rehabilitation Engineering. 14, 4, p. 427-437 11 p.

Research output: Contribution to journalArticle

51 Citations (Scopus)
2004

A 230-nW 10-s time constant CMOS integrator for an adaptive nerve signal amplifier

Rieger, R., Demosthenous, A. & Taylor, J., 2004, In : IEEE Journal of Solid-State Circuits. 39, 11, p. 1968-1975 8 p.

Research output: Contribution to journalArticle

33 Citations (Scopus)

Design of an adaptive interference reduction system for nerve-cuff electrode recording

Demosthenous, A., Taylor, J., Triantis, I. F., Rieger, R. & Donaldson, N., 2004, In : IEEE Transactions on Circuits and Systems. Part I: Regular Papers. 51, 4, p. 629-639 11 p.

Research output: Contribution to journalArticle

19 Citations (Scopus)

Experimental determination of compound action potential direction and propagation velocity from multi-electrode nerve cuffs

Rieger, R., Taylor, J., Comi, E., Donaldson, N., Russold, M., Mahony, C. M. O., McLaughlin, J. A., McAdams, E., Demosthenous, A. & Jarvis, J. C., 2004, In : Medical Engineering & Physics. 26, 6, p. 531-534 4 p.

Research output: Contribution to journalArticle

20 Citations (Scopus)

Multiple-electrode nerve cuffs for low-velocity and velocity-selective neural recording

Taylor, J., Donaldson, N. & Winter, J., 2004, In : Medical and Biological Engineering and Computing. 42, 5, p. 634-643 10 p.

Research output: Contribution to journalArticle

56 Citations (Scopus)
2003

Design of a low-noise preamplifier for nerve cuff electrode recording

Rieger, R., Taylor, J., Demosthenous, A., Donaldson, N. & Langlois, P. J., 2003, In : IEEE Journal of Solid-State Circuits. 38, 8, p. 1373-1379 7 p.

Research output: Contribution to journalArticle

62 Citations (Scopus)
2002

A 100 Mb/s, 2.8 V CMOS current-mode analogue Viterbi decoder (invited paper)

Demosthenous, A. & Taylor, JT., 2002, In : IEEE Journal of Solid-State Circuits (JSSC). 37, 7, p. 904-910 7 p.

Research output: Contribution to journalArticle

25 Citations (Scopus)

A 100-Mb/s 2.8-V CMOS current-mode analog Viterbi decoder

Demosthenous, A. & Taylor, J., Jul 2002, In : IEEE Journal of Solid-State Circuits. 37, 7, p. 904-910 7 p.

Research output: Contribution to journalArticle

25 Citations (Scopus)
3 Citations (Scopus)
2001

An implant for chronic selective stimulation of nerves (invited paper)

Bugbee, M., Donaldson, N. D. N., Lickel, A., Rijkhoff, N. J. M. & Taylor, J., Jan 2001, In : Medical Engineering & Physics. 23, 1, p. 29-36

Research output: Contribution to journalArticle

16 Citations (Scopus)